15 Speed
Operation in the 15 Speed
Switched inputs at
Fault Reset as defined in Table
Figure 3-19 15 Speed 2-Wire Control Connection Diagram
OPEN disables the control and motor coasts to a stop.
Analog GND
Analog Input 1
Pot Reference
No Connection Analog Input +2
Analog Input
J1
1
2
3
4
5
setting.
Programmable Output
Programmable Output
Analog Out 1
Analog Out 2
Enable
Forward Run
6
7
8
Reverse Run
Switch 1
Switch 2
Switch 3
Switch 4
Accel/Decel/S Select 1
External Trip
Opto In Common
Refer to Figure
9
10
11
12
13
14
15
16
17
See recommended terminal tightening torques in Section 7.
Table 3-11 Switch Truth Table for 15 Speed, 2 Wire Control Mode
Function |
|
|
|
|
|
|
|
|
|
Preset 1 | Open | Open | Open | Open |
Preset 2 | Closed | Open | Open | Open |
Preset 3 | Open | Closed | Open | Open |
Preset 4 | Closed | Closed | Open | Open |
Preset 5 | Open | Open | Closed | Open |
Preset 6 | Closed | Open | Closed | Open |
Preset 7 | Open | Closed | Closed | Open |
Preset 8 | Closed | Closed | Closed | Open |
Preset 9 | Open | Open | Open | Closed |
Preset 10 | Closed | Open | Open | Closed |
Preset 11 | Open | Closed | Open | Closed |
Preset 12 | Closed | Closed | Open | Closed |
Preset 13 | Open | Open | Closed | Closed |
Preset 14 | Closed | Open | Closed | Closed |
Preset 15 | Open | Closed | Closed | Closed |
Fault Reset | Closed | Closed | Closed | Closed |
MN722 | Receiving & Installation |