Table 5-2 Inverter Control Board Fault Messages

 

 

FAULT MESSAGE

DESCRIPTION

 

 

Current Sens FLT

Defective phase current sensor or open circuit detected between control board and current

 

sensor.

DC Bus High

Bus over voltage condition occurred.

DC Bus Low

Bus under voltage condition occurred.

Encoder Loss

Encoder coupling slipping or broken; noise on encoder lines, encoder power supply loss or

 

defective encoder.

External Trip

An open circuit on J1-16 typically indicating an external over temperature condition.

Following Error

Excessive following error detected between command and feedback signals.

GND FLT

Low impedance path detected between an output phase and ground.

INT Over-Temp

Temperature of control heatsink exceeded safe level.

Invalid Base ID

Control does not recognize power base ID.

Inverter Base ID

Control board installed on power base without current feedback.

Line Regen FLT

Indicates a converter section fault.

Logic Supply FLT

Logic power supply not working properly.

Lost User Data

Battery backed RAM parameters have been lost or corrupted.

 

When fault cleared (Reset), the control should reset to factory preset values.

Low INIT Bus V

Insufficient bus voltage on startup.

Memory Error

EEPROM error occurred. Contact Baldor.

New Base ID

Control board sensed a different power base since last time it was powered up.

No Faults

Fault log is empty.

No EXB Installed

Programmed parameter requires an expansion board.

Over Current FLT

Instantaneous over current condition detected by bus current sensor.

Overload - 1 min

Output current exceeded 1 minute rating.

Overload - 3 sec

Output current exceeded 3 second rating.

Over speed

Motor RPM exceeded 110% of programmed MAX Motor Speed.

mP Reset

Power cycled before the residual Bus voltage reached 0VDC.

PWR Base FLT

Desaturation of power device occurred or bus current threshold exceeded.

Resolver Loss

Resolver feedback problem is indicated (if resolver used).

Torque Prove FLT

Unbalanced current between all 3 motor phases.

User Fault Text

Custom software operating fault occurred.

 

 