Altinex MT105-100, MT105-101 manual 12. …P Path, SW Switch, ImOx, Clr

Page 14

MULTI-TASKER™

12.[…P] – PATH

This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded. See the examples in [ON] and [OFF] commands.

Example:

There is an MT105-100in slot 4. Currently, Input 1 is connected to all outputs and all outputs are on. The path command has been used to set Input 2 to Output 1 and turn off Outputs 2 and 3 at the same time. If checking the status prior to sending the [SW] command, the feedback will appear as follows for the above connection settings:

In01-Out1 ON P=2

In01-Out2 ON P=OFF

In01-Out3 ON P=OFF

In01-Out4 ON

In01-Out5 ON

In01-Out6 ON

In01-Out7 ON

The notation "P=" at the end of the line indicates the path condition is active. "P=2" on the Output 1 line indicates that after the [SW] command, Input 2 will be connected to Output 1.

The notation "P=OFF" on lines 2 and 3 indicates that Outputs 2 and 3 will be turned off after the [SW] command is executed.

13.[SW] – SWITCH

This command immediately connects inputs and outputs previously set with the path command. The command switches all paths set on this card and all other cards in the enclosure.

400-0131-004

13

Example:

The following commands set the path for turning on Output 1 of the card in slot 6 and turning off Output 3 of the card in slot 9. Nothing happens until the [SW] command is sent. At that time, Output 1 will be enabled and Output 3 will be disabled.

[ON1C6P] , [OFF3C9P] and [SW]

14.[ImOx]

This command connects a single input to a single output in the current matrix configuration.

Command Format: [ImOxCnUi]

m= Input (m= # from 1 to 16) x = Output (x = # from 1 to 8)

Cn = Card ID (n = slot # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Connect Input 1 to Output 1 for the MT105-100in slot 5. Send the command [I1O1C5] and Input 1 will be connected to Output 1.

15.[ImO*]

This command connects a single input to all the outputs in the current matrix configuration.

Command Format: [ImO*CnUi]

m

= Input (m = # from 1 to 16)

Cn

= Card ID (n = slot # from 1 to max slots)

Ui

= Unit ID (i = # from 0 to 9)

Example:

Connect Input 1 to all outputs for the MT105-100in slot 5. Send the command [I1O*C5] and Input 1 will be connected to all outputs.

16.[CLR]

This command performs a reset of the card and restores settings to the factory defaults.

Command Format: [CLRCnUi]

Cn

= Card ID (n = # from 1 to max slots)

Ui

= Unit ID (i = # from 0 to 9)

13

Image 14
Contents MT105-100/MT105-101 Troubleshooting Guide General InstallationCleaning FCC / CE NoticeMT105-100/MT105-101 Description of MT105-100/101 Diagram 1 Typical Setup Diagram 2 Internal View MT105-100 Diagram 3 Internal View MT105-101 1 RS-232 Interface Description of CommandsRS-232 Control VERSAVEDC04 VERCnS STA1 Group Operation STA0Single Card Operation Path Operation11. …F Feedback OFF10. …S Save ImOx SW Switch12. …P Path ImOFBD SIDnCi RSISIDn SID+nHelp TestMATmXy 26. WR29. RD RMCRMG Menu Command Definitions Summary of CommandsMenu Mode VERMain Menu Using Menu ModeMenu Types SUB MenusSelect Card/Group for Control ESCMenu Mode Examples ALTINEX, INC Limited WARRANTY/RETURN Policy Contact InformationNo Display Toll Free 1-800-ALTINEX