23.[TEST]

This command performs a test on the internal memory. Upon completion, the system will display the results. If there are no problems, the system will display the following:

MEMORY IS GOOD

Otherwise, failures will be indicated.

Command Format: [TESTCnUi]

Cn = Card ID (n = slot # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

There is an MT105-100/101in slot 10. In order to test the internal memory, send the command [TESTC10].

24.[MATmXy]

This matrix command allows the matrix switcher to be setup for different matrix sizes. The tables below show how the inputs and outputs will be configured when the matrix is changed.

Example:

In the 8x4 configuration, when Input 1 is connected to Output 8, the entire channel, 1a and 1b, will be switched to outputs 8a and 8b respectively.

Command Format: [MATmXyCnUi]

m = number of inputs (m = 16, 8 or 4)

y = number of outputs (y = 8, 4 or 2)

Cn = Card ID (n = slot # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

4 X 2

IN

 

OUT

O3a

O1a

 

O1a

O3b

O1b

 

O1b

O3c

O1c

 

O1c

O3d

O1d

 

O1d

O4a

O2a

 

O2a

O4b

O2b

 

O2b

O4c

O2c

 

O2c

O4d

O2d

 

O2d

25.[HELP]

This command displays information available for the Multi-Tasker interface commands.

Command Format: [HELPCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

In order to display the RS-232 commands available for the MT105-100/101card in slot 4, send the command [HELPC4]. The commands along with a brief description will be displayed in the terminal window.

GROUP COMMANDS

The next few commands are group commands. The use of groups allows several boards, with the same functions, to be controlled simultaneously with a single command. These commands apply to all cards, not only the MT105-100/101.

26.[WR]

This command groups multiple cards in the enclosure allowing all the group members to be

16 X 8

IN

O9 O1

O10 O2

O11 O3

O12 O4

O13 O5

O14 O6

O15 O7

O16 O8

OUT

O1

O2

O3

O4

O5

O6

O7

O8

8 X 4

IN

O5a O1a

O5b O1b

O6a O2a

O6b O2b

O7a O3a

O7b O3b

O8a O4a

O8b O4b

OUT

O1a

O1b

O2a

O2b

O3a

O3b

O4a

O4b

controlled simultaneously with the same command. Each Multi-Tasker™ unit may define a maximum of eight groups.

In Multi-Tasker™ systems with audio and video cards, boards are typically grouped as follows:

Group 1 = Video Cards

Group 2 = Audio Cards

Group 3 = Video and Audio Cards

400-0131-004

16

16

Image 17
Contents MT105-100/MT105-101 Troubleshooting Guide Cleaning InstallationGeneral FCC / CE NoticeMT105-100/MT105-101 Description of MT105-100/101 Diagram 1 Typical Setup Diagram 2 Internal View MT105-100 Diagram 3 Internal View MT105-101 RS-232 Control Description of Commands1 RS-232 Interface VERSAVEDC04 VERCnS STA1 Single Card Operation STA0Group Operation Path Operation11. …F Feedback OFF10. …S Save 12. …P Path SW SwitchImOx ImOFBD SIDn RSISIDnCi SID+nMATmXy TestHelp 26. WR29. RD RMCRMG Menu Mode Summary of CommandsMenu Command Definitions VERMenu Types Using Menu ModeMain Menu SUB MenusESC Select Card/Group for ControlMenu Mode Examples No Display Limited WARRANTY/RETURN Policy Contact InformationALTINEX, INC Toll Free 1-800-ALTINEX