Altinex MT105-100, MT105-101 manual Rmc, Rmg, 29. RD

Page 18

MULTI-TASKER™

Command Format: [WRCn1Cn2…GkUi]

Cn = Card ID (n = slot # from 1 to max slots)

Gk = Group number (k = # from 1-8)

Ui = Unit ID (i = # from 0-9)

Example:

Group cards 2, 4, and 6 as group 5 of Unit ID 1 by sending the command [WRC2C4C6G5U1]. After executing this command, cards 2, 4 and 6 will be grouped together as group 5 of Unit ID 1. The system will return the following feedback:

[G5=C2C4C6]

Now, when a command is sent to G5, each board in G5 will execute the same command.

27.[RMC]

This command may be used to remove one or more group members from a group. Reset the system after using this command for all changes to take effect.

Command Format: [RMCn1Cn2…GkUi] Cn = Card ID (n= # from 1 to max slots)

Gk = Group ID (k = # from 1-8)

Ui = Unit ID (i = # from 0-9)

Example:

Group 5 consists of the cards located in slots numbered 2, 4, and 6. Remove just cards 4 and 6 from the group by sending the command [RMC4C6G1]. The system will return the following feedback:

[G5=C2]

28.[RMG]

This command may be used to delete an entire group, or all groups.

REMOVE A GROUP

Remove all the members from the group, effectively deleting the group.

Command Format: [RMGkUi]

Gk = Group ID (k = # from 1-8)

Ui = Unit ID (i = # from 0-9)

Example:

Group 5 consists of the cards located in slots number 2, 4 and 6. Remove all cards from the group by sending the command [RMG5]. The system will return the following feedback:

[G5=0]

REMOVE ALL GROUPS

Remove all the members from every group, effectively deleting all groups.

Command Format: [RMG*Ui]

Ui = Unit ID (i = # from 0-9)

Example:

Group 5 consists of cards 2, 4 and 6. Group 2 consists of cards 1, 2, 3, 4 and 5. Delete all the groups by sending the command [RMG*]. The system will return the following feedback:

G1-G8:EMPTY

29.[RD]

This command reads and then displays the members in each group.

Command Format: [RDGkUi]

Gk = Group ID (k = # from 1-8)

Ui = Unit ID (i = # from 0-9)

Example:

The cards in slots 2, 4 and 6 are part of group 5. Read the member data for group 5, by sending the command [RDG5]. The system will return feedback as follows:

[G5=C2C4C6]

The feedback shows G5 (group 5) and then the cards that make up group 5. In this case, group 5 includes C2, C4 and C6.

400-0131-004

17

17

Image 18
Contents MT105-100/MT105-101 Troubleshooting Guide General InstallationCleaning FCC / CE NoticeMT105-100/MT105-101 Description of MT105-100/101 Diagram 1 Typical Setup Diagram 2 Internal View MT105-100 Diagram 3 Internal View MT105-101 1 RS-232 Interface Description of CommandsRS-232 Control VERVER CnSSAVEDC04 STA1 Group Operation STA0Single Card Operation Path OperationOFF 10. …S Save11. …F Feedback ImOx SW Switch12. …P Path ImOFBD SIDnCi RSISIDn SID+nHelp TestMATmXy 26. WRRMC RMG29. RD Menu Command Definitions Summary of CommandsMenu Mode VERMain Menu Using Menu ModeMenu Types SUB MenusSelect Card/Group for Control ESCMenu Mode Examples ALTINEX, INC Limited WARRANTY/RETURN Policy Contact InformationNo Display Toll Free 1-800-ALTINEX