The Group ID is a number representing a group of cards defined with the [WR] command. When using the Group ID, all cards in the group will perform the given instruction.
Changing the position of a card will significantly affect the commands recorded on software definitions or third party control systems.
The Unit ID has a value from 0 to 9. Unit ID 0 should be used for single unit operation. If the Unit ID is set to zero, each command may be used without Ui. Use the command [SETU0], as explained in the
Example:
[VERC3]: For Unit ID Zero
[VERC3Ui]: For Unit ID other than Zero
[VERC3]: Equivalent to [VERC3U0]
1.[VER]
This command displays the software version and model for the
Command Format: [VERCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
There is an
= Card Model Number | |
= Software Version | |
C04 | = Card ID |
2. [C]
This command displays the status of the card and connections of the matrix switcher.
Command Format: [CnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
An
Matrix:16X8
NOTE: If there is no card in slot 2, sending the command [C2] will not return any feedback.
3.[CnS]
This command saves the input to output settings as well as the output enable status. This configuration will be restored after the system is reset or powered off then on.
Command Format: [CnSUi]
Cn = Card ID (n = # from 1 to max slots)
S = save configuration
Ui = Unit ID (i = # from 0 to 9)
Example:
Input 1 is connected to all 8 outputs, but only 1 through 4 are on. Send the command [C4S] for slot 4, and receive the following feedback:
Matrix:16X8
[SAVEDC04]
9 |
9