TV Operation
Analogue menu
A
Calls up the TV menu
Selecting the standard
With this softkey, the following standards can be selected: B/G, D/K, I, L, M, M – jap. (Japan) and N. Refer to the audio carrier table.
In this menu, the channel setting can be changed using the cursor buttons, ◄►. In the RP menu, the receiving frequency can be changed in this manner.
Audio carrier table for TV reception
The given audio carrier frequencies are based on the video audio carrier
spacing
Standard | Audio carrier 1 | Audio carrier | Audio carrier (1 +2 | NICAM | |
(sc1) | (sc 2) | sc) | (nicam) | ||
| |||||
B/G | 5.50 MHz | 5.74 MHz | sc 1: 5.50 MHz | 5.85 MHz | |
sc 2: 5.74 MHz | |||||
|
|
|
| ||
L | 6.50 MHz (AM) |
|
| 5.85 MHz | |
D/K | 6.50 MHz | 6.26 MHz | sc 1: 6.50 MHz | 5.85 MHz | |
sc 2: 6.26 MHz | |||||
|
|
|
| ||
I | 6.00 MHz |
|
| 6.552 MHz | |
M | 4.50 MHz | 4.72 MHz | sc 1: 4.50 MHz |
| |
sc 2: 4.72 MHz |
| ||||
|
|
|
| ||
M (Japan) | 4.50 MHz |
|
|
| |
N | 4.50 MHz |
|
|
|
Selecting the audio carriers
By pressing the button, the MSK 33 can be set to the following reception types:
Audio carrier 1 (sc1)
Audio carrier 2 (sc2)
Stereo (sc1 + sc2)
NICAM (nicam)
Level-dependent acoustic signal
In the function, „level beep,“ the acoustic signal is generated, whose pitch is pro- portionate to the received signal level. With this, it is possible to optimally align the receiving antenna to a transmitter.
Carrying out measurements
By pressing the button, the MSK 33 is set to analogue reception and measures the following values:
-Audio carrier spacing of TT1 (sc1) and TT2 (sc2)
-Nicam audio carrier spacing (if available)
– Nicam bit error rate (BER)
45