Technical Appendix
Overview of DiSEqC commands
Command overview framing byte
| Description |
E0 | Commando from master, one time transmission |
E1 | Commando from master, repeated transmission |
E2 | Commando from master, answer expected, first transmission |
E3 | Commando from master, answer expected, repeated transmission |
E4 | Answer from slave, „OK“, no error detected |
E5 | Answer from slave, commando is not supported by slave |
E6 | Answer from slave, parity error is detected |
E7 | Answer from slave, commando not recognised |
Command overview address byte
Description | |
00 | All units |
10 | Each LNB, Matrix or SMATV |
11 | LNB |
12 | LNB with |
14 | Matrix (Switcher) |
15 | Matrix (Switcher) with |
18 | SMATV |
20 | Every polarizer |
21 | Full skew for linear polarisation |
22 | Polarizer gradually set |
30 | Every positioner |
31 | Polar / azimuth positioner |
32 | Elevation positioner |
33 | Combined positioner |
34 | LNB positioner |
40 | |
41 | Signal strength |
60 | Reserved for assigned addresses |
70 | „Intelligent slave interface“ for „Proprietary |
71 | Interface for subscriber and controlled head ends |
Fx | CEM extension |
98