Allied Telesis 613-001480 manual What’s New in Version, New Software Features, Resolved Issues

Page 3

AT-S94 Version 3.0.0.41 Software Release Notes

What’s New in Version 3.0.0.41

New Software Features

ˆNone

Resolved Issues

ˆIn some cases where more than one switch has the same STP Bridge Priority value in a network, the switch with the higher MAC address would be elected as the STP root bridge. This issue has been resolved.

Operational Notes

ˆ100 Mbps SFP: Switch over back to fiber fails after fiber link restored. It happens when an LCP155A4HSR 100M SFP is used when backup Copper link is 1G. Recommended User Work Around: Works fine when fiber and Copper speeds are similar and there are no issues with different SFP model.

ˆPort Mirroring: Port mirroring closes the port and opens it again.

Recommended User Work Around: Not required.

ˆTAB functionality: Use of the Tab key does not complete the command Interface range VLAN all and the command Switchport general allowed VLAN.

Recommended User Work Around: Type in the full command.

ˆSNMP - EWS > SNMP > Notify > Filters: Cannot add or modify filter with name containing special characters.

Recommended User Work Around: Do not use special characters.

ˆTime - EWS > System > System Time: The current day becomes undefined after changing Time Zone Offset.

Recommended User Work Around: The current day will be displayed correctly when the switch is reset.

ˆWeb Response Time: Upon full table configuration it takes longer time to open the page IPv6 Neighbors and the page Statistics->RMON Alarm.

ˆFlow Control: Flow control does not work on the Gigabit ports.

Recommended User Work Around: No work around.

ˆEncryption: It is impossible to add MD5/SHA keys via EWS.

Recommended User Work Around: Use CLI commands.

ˆSyslog: Fail to add one syslog server with a description of maximum length including some space.

Recommended User Work Around: Do not use spaces and avoid using the maximum allows length of the description.

ˆLLDP: When in mixed stack of PoE and Non PoE units, you can configure the PoE-PSE optional TLVs for non-PoE ports and these non-PoE ports will be advertised. Recommended User Work Around: Do not configure the PoE-PSE optional TLVs for non-PoE ports, so that this information will not be advertised.

ˆTACACS: When using the single connection option, the first login or “enable” attempts will fail, but the retry works.

Recommended User Work Around: Use the multiple connection option (default setting).

PN 613-001480 Rev A

3

Allied Telesis, Inc.

Image 3
Contents AT-S94 Version AT-8000S Switch Software Release Notes Product Documentation and Software Supported PlatformsOperational Notes New Software FeaturesResolved Issues What’s New in VersionKnown Issues New Hardware FeaturesRecommended User Work Around Use DVA instead Version 3.0.0.41 Upgrade Process For a stack configuration Software Installed with Incorrect Bootloader Version History of Resolved IssuesFeatures History LED Description LED Indicationˆ Dot1x Legacy compliant CLI Command Description of Functionality ˆ 802.1ab Lldp Following 802.1x feature enhancements will be supportedInterim SW Upgrade Procedure from VersionCopy tftp//192.168.1.10/ats94-interim.ros image Copy tftp//192.168.1.10/s94bv10107.rfb boot Reload Contacting Allied Telesis Online Support Email and Telephone Support Warranty