Allied Telesis 613-001480 manual Version 3.0.0.41 Upgrade Process

Page 5

AT-S94 Version 3.0.0.41 Software Release Notes

Version 3.0.0.41 Upgrade Process

You must have the correct software and bootloader installed on your switch before beginning the upgrade process to Version 3.0.0.41. Perform the following procedure:

Note

If you have a stacked configuration, all switches must be running the latest bootloader and the same software version before you upgrade the software for the stack.

Note

You can download Version 3.0.0.41 files from our web site at www.alliedtelesis.com. Refer to “Management Software Updates” on page 16 for instructions on how to navigate to the software updates page for the AT-8000S. All of the file names referenced below are contained in the zip file that you download.

1.Log into the switch.

2.For a successful software upgrade of your AT-8000S switch, it is mandatory that you first install the latest boot loader file (s94bv10107.rfb). You can find this file in the Latest_Boot_Loader folder that you have downloaded from the Allied Telesis web site.

3.Verify that your switches are running the correct boot loader and management software by using the following command:

show version

4.If your AT-8000S series switch has Version 1.0.0.25 (or earlier) currently installed on it, go to the “Upgrade Procedure from Version 1.0.0.25” on page 12. and follow the steps to upgrade to Version 3.0.0.41. If your AT-8000S series switch has Version 1.1.0.32 or later installed on it, go to the next step to upgrade to Version 3.0.0.41.

5.With information displayed from the “show version” command, copy the boot version number exactly as shown. Using this number as the password, extract the ats94-30041.ros software upgrade file from the ats94-30041.zip file.

PN 613-001480 Rev A

5

Allied Telesis, Inc.

Image 5
Contents AT-S94 Version AT-8000S Switch Software Release Notes Product Documentation and Software Supported PlatformsResolved Issues New Software FeaturesWhat’s New in Version Operational NotesRecommended User Work Around Use DVA instead Known IssuesNew Hardware Features Version 3.0.0.41 Upgrade Process For a stack configuration Software Installed with Incorrect Bootloader Version History of Resolved Issuesˆ Dot1x Legacy compliant Features HistoryLED Description LED Indication CLI Command Description of Functionality ˆ 802.1ab Lldp Following 802.1x feature enhancements will be supportedInterim SW Upgrade Procedure from VersionCopy tftp//192.168.1.10/ats94-interim.ros image Copy tftp//192.168.1.10/s94bv10107.rfb boot Reload Contacting Allied Telesis Online Support Email and Telephone Support Warranty