AT-S94 Version 3.0.0.41 Software Release Notes

Upgrade Procedure from Version 1.0.0.25

All software released after version 1.0.0.25 requires additional FLASH sectors beyond the current amount of FLASH sectors currently allocated for the image. Therefore the FLASH sectors must be reordered before downloading the new software. This will be accomplished by first downloading an interim version, and only after that loading the actual released version.

Note

Due to new Board Support Package (BSP) there is also an updated Boot code: version

1.0.0.7.This can be uploaded regardless of the SW image (ROS version) running on the device. Therefore, boot upgrade can be performed before or after the upgrade procedure described below

The interim version provided reorders the FLASH allocation without the need to erase the FLASH and downloading the new software via the serial cable using XMODEM. Hence, the AT-8000S software upgrade procedure can be performed via TFTP server. The block diagram of this procedure is shown in Figure 1.

 

Steps 3 - 5

 

Steps 6 - 10

 

 

SW Download

 

SW Download

 

 

via

 

via

 

Version

TFTP + Reboot

Interim SW

TFTP + Reboot

Final SW

 

 

1.0.0.25 SW

 

 

 

 

Figure 1. Software Upgrade Process from Version 1.0.0.25 The existing configuration is retained including MAC address and serial number.

Note

During the software upgrade ensure the following:

Ensure that the device is not powered down or that a power cable is not disconnected during the software upgrade. If the device is powered down or if a cable is disconnected, once device is reconnected the software upgrade must be downloaded via XMODEM

Ensure that the device configuration is backed up to an external server/station.

Do not use the interim code drop for Quality Assurance testing, field upgrades etc; use only the final code drop

When running the interim version, the initialization stage takes a relatively long time

The user will have to run the following steps in order to successfully completing the upgrade procedure:

1. Back up configuration files to an external device.

PN 613-001480 Rev A

12

Allied Telesis, Inc.

Image 12
Contents AT-S94 Version AT-8000S Switch Software Release Notes Supported Platforms Product Documentation and SoftwareNew Software Features Resolved IssuesWhat’s New in Version Operational NotesKnown Issues New Hardware FeaturesRecommended User Work Around Use DVA instead Version 3.0.0.41 Upgrade Process For a stack configuration Software Installed with Incorrect Bootloader History of Resolved Issues VersionFeatures History LED Description LED Indicationˆ Dot1x Legacy compliant CLI Command Description of Functionality Following 802.1x feature enhancements will be supported ˆ 802.1ab LldpUpgrade Procedure from Version Interim SWCopy tftp//192.168.1.10/ats94-interim.ros image Copy tftp//192.168.1.10/s94bv10107.rfb boot Reload Online Support Email and Telephone Support Warranty Contacting Allied Telesis