Carrier 69NT40-511-199, 69NT40-521 manual Installation, Procedure for loading Operational Software

Models: 69NT40-521 69NT40-511-1 69NT40-511-199

1 138
Download 138 pages 33.05 Kb
Page 123
Image 123

NOTE

This packaging has been designed to protect the Controller/DataCORDER module from both physical and electrostatic discharge damage during storage and transit.

Installation:

Install the module by reversing the steps in section 6.27.b.

Torque values for mounting screws (item 1, Figure 6-31) are 0.23 mkg (20 inch-pounds), and 0.12 mkg (10 inch-pounds) for all connectors (MA, MB, MC, KA & KB).

6.27.1 Controller/DataCORDER

Programming

Procedure

 

To load new software into the module, the programming card is inserted into the programming/software port.

WARNING

The unit must be OFF whenever a programming card is inserted or removed from the programming/software port.

The metal door on the programming card must be facing to the left when inserting.

Procedure for loading Operational Software:

a.Turn unit OFF, via start-stop switch (ST).

b.Insert the programming card for Operational Software into the programming/software port. (See Figure 6-31)

c.Turn unit ON, via start-stop switch (ST).

d.The Display module will read:

(1.) If the correct card is being used the digital display will alternate back and forth between the messages “rEV XXXX” and “Press EntR.”

(2.) If a defective card is being used: the Display will blink the message “bAd CArd.” (Turn start-stop switch OFF and remove the card.)

e.Press the ENTER key on the keypad.

f.The Display will show the message “Pro SoFt.” This message will last for up to one minute.

g.The Display module will read:

(2.) If a problem occurs while loading the software: the Display will blink the message “Pro FAIL” or “bad 12V.” (Turn start-stop switch OFF and remove the card.)

h.Turn unit OFF, via start-stop switch (ST).

i.Remove the programming card from the programming/software port.

j.Turn unit ON, via start-stop switch (ST).

Procedure for loading Configuration Software:

a.Turn unit OFF using start-stop switch (ST).

b.Insert the programming card, for Configuration Software, into the programming/software port. (See Figure 6-31.)

c.Turn unit ON using start-stop switch (ST).

d.The Display module will read:

(1.) If the correct card is being used, the digital display will show “nt40” on the left LCD display and “511XXX” on the right LCD display. “XXX” will indicate the dash number for a given unit model number, use the UP or DOWN ARROW key to scroll through the list to obtain the proper model dash number (i.e., For the unit 69NT40-511-105, the left display will show “nt40,” press the UP or DOWN ARROW key until the right display shows “511105.”)

(2.) If a defective card is being used, the Display will blink the message “bAd CArd.” (Turn start-stop switch OFF and remove the card.)

e.Press the ENTER key on the keypad.

f.The Display module will read:

(1.) When the software loading has successfully completed, the Display will show the message “EEPrM donE.”

(2.) If a problem occurs while loading the software, the Display will blink the message “Pro FAIL” or “bad 12V.” Turn start-stop switch OFF and remove the card.

g.Turn unit OFF using start-stop switch (ST).

h.Remove the programming card from the programming/software port.

i.Turn unit ON using start-stop switch (ST).

6

(1.) When the software loading has successfully

6.27.2 Controller Trouble-Shooting

 

completed: the Display will show the message

A group of test points (tp) are provided on the Controller

“Pro donE.”

(see Figure 6-31, item 3) for trouble-shooting electrical

6-29

T-268-07

SECTION

Page 123
Image 123
Carrier 69NT40-511-199, 69NT40-521 Installation, Procedure for loading Operational Software, Controller Trouble-Shooting