2.2 | REFRIGERATION SYSTEM DATA |
|
|
|
| ||
|
|
|
|
|
|
| |
|
| Number of Cylinders |
|
| 6 | ||
|
|
|
|
|
|
| |
|
| Model |
|
| 06DR | ||
|
|
|
|
|
|
| |
|
| CFM |
|
| 41 | ||
|
|
|
|
| |||
|
| Weight (Dry) | 118 kg (260 lb) - | ||||
|
|
|
|
|
| ||
i. | Compressor/Motor Assembly | 129.39 kg (285.25 lb) - | |||||
| |||||||
|
|
|
|
| |||
|
| Approved Oil | Castrol Icematic | ||||
|
|
|
|
| |||
|
| Oil Charge | 3.6 liters (7.6 U.S. pints) | ||||
|
|
|
|
| |||
|
|
| The oil level range, with the compressor off, | ||||
|
| Oil Sight Glass | should be between the bottom and | ||||
|
|
| level of the capacity of the sight glass. | ||||
|
| Verify at |
|
|
|
| |
j. | Expansion Valve Superheat | (0 _F) container box | 4.48 to 6.67 _C (8 to 12 _F) | ||||
|
| temperature |
|
|
|
| |
k. Heater Termination Thermostat | Opens | 54 (¦ 3) _C = 130 (¦ 5) _F | |||||
Closes | 38 (¦ 4) _C = 100 (¦ 7) _F | ||||||
l. | High Pressure Switch | Cutout | 25 (¦ 1.0) kg/cm@ = 350 (¦ 10) psig | ||||
|
|
|
|
| |||
18 (¦ 0.7) kg/cm@ = 250 (¦ 10) psig | |||||||
|
| ||||||
|
|
|
|
| |||
|
| Unit Configuration | Charge Requirements | ||||
|
|
|
|
|
| ||
|
| 2* row condenser |
| 4* row condenser | |||
|
|
|
| ||||
m. Refrigerant Charge |
|
|
|
|
| ||
4.5 kg (9.0 lbs) |
|
| 5.22 kg (11.5 lbs) | ||||
|
| Condenser |
|
| |||
|
|
|
|
|
| ||
|
| Receiver | 3.74 kg (8.25 lbs) |
| 4.88 kg (10.75 lbs) | ||
|
|
|
|
|
|
| |
|
| * Refer to Table |
|
|
| ||
|
|
|
|
|
|
| |
|
| NOTE |
|
|
|
| |
| When replacing the components (n.), (o.) and (p.) in section 2.2, refer to the installation instructions | ||||||
| included with the ordered new part for additional information. |
|
|
| |||
|
|
|
| ||||
n. Fusible Plug | Melting point | 99 _C = (210 _F) | |||||
|
|
|
|
| |||
Torque | 6.2 to 6.9 | mkg (45 to 50 | |||||
|
| ||||||
|
|
|
| ||||
o. Sight Glass/Moisture Indicator | Torque | 8.9 to 9.7 | mkg (65 to 70 | ||||
|
| Bursts at | 35 5% kg/cm@ = (500 5% psig) | ||||
|
|
|
|
|
|
| |
|
| Torque | 1.4 to 2 mkg (10 to 15 | ||||
p. Rupture Disc | (P/N | ||||||
|
|
|
| ||||
|
| Torque | 6.2 to 6.9 | mkg (45 to 50 | |||
|
| (P/N | |||||
|
|
|
|
|
| ||
|
|
| The condenser fan will start if the condenser | ||||
|
| Condenser Fan Starts | pressure is greater than 14.06 kg/cm@ (200 | ||||
|
| psig) OR the condenser fan is OFF for more | |||||
|
|
| |||||
q. Condenser Pressure |
| than 60 seconds. | |||||
| Transducer (CPT) |
| The condenser fan will stop if the condenser | ||||
|
| Condenser Fan Stops | pressure is less than 9.14 kg/cm@ (130 psig) | ||||
|
| AND the condenser fan remains ON for at least | |||||
|
|
| |||||
|
|
| 30 seconds. | ||||
r. | Unit Weight | Refer to unit model number plate, see Figure | |||||
|
|
| |||||
s. Water Pressure Switch | 0.5 ¦ 0.2 kg/cm@ (7 ¦ 3 psig) | ||||||
| (Optional) | Cutout | 1.6 ¦ 0.4 kg/cm@ (22 ¦ 5 psig) |