SReal Time Clock (RTC) Modification S
S Trip Start
SISO Trip Header (Must be entered first via Interrogation program)
SEconomy Mode Start S Economy Mode End S “Auto 2”
S Bulb Mode changes S Bulb Mode End
S USDA Trip Comment
S CTD Controlled Atmosphere Information S Humidification Start
S Humidification End
S USDA Probe Calibration
3.3.2DataCORDER Configuration
NOTE
The DataCORDER software is integrated with the Controller software.
Configuration to factory installed default configuration is achieved via a common configuration card used for controller functions, see section 3.1.2.
Changes to the factory default configuration must be made with the Interrogation device.
Configuration:
Tells the operational software what physical components are built into the container unit, how many sensors to record, what recording interval should be used, etc..
ITEM | SETTING | FACTORY | |
DEFAULT | |||
|
| ||
Sensor Logging | Average or | Average | |
(Network) | Snapshot | ||
| |||
Sensor Logging | Average, |
| |
Snapshot or | Average | ||
(Thermistor) | |||
USDA |
| ||
|
| ||
|
|
| |
Sensor Format | 1 or 2 byte | 1 byte | |
|
|
| |
Sensor | Refer to section | 2 sensors | |
Configuration | 3.3.5.f. | ||
| |||
Logging Interval | 15, 30, 60 or | 60 minutes | |
120 minutes | |||
|
|
Configuration cards are available thru CTD Replacement Components Group.
The use of a programming card in the field should only occur under unusual circumstances, such as a physical component in the container unit is changed to a different component, resulting in a new configuration for the unit.