SReal Time Clock (RTC) Modification S Pre-Trip result & data

S Trip Start

SISO Trip Header (Must be entered first via Interrogation program)

SEconomy Mode Start S Economy Mode End S “Auto 2” Pre-Trip Start S “Auto 2” Pre-Trip End S Bulb Mode Start

S Bulb Mode changes S Bulb Mode End

S USDA Trip Comment

S CTD Controlled Atmosphere Information S Humidification Start

S Humidification End

S USDA Probe Calibration

3.3.2DataCORDER Configuration

NOTE

The DataCORDER software is integrated with the Controller software.

Configuration to factory installed default configuration is achieved via a common configuration card used for controller functions, see section 3.1.2.

Changes to the factory default configuration must be made with the Interrogation device.

Configuration:

Tells the operational software what physical components are built into the container unit, how many sensors to record, what recording interval should be used, etc..

ITEM

SETTING

FACTORY

DEFAULT

 

 

Sensor Logging

Average or

Average

(Network)

Snapshot

 

Sensor Logging

Average,

 

Snapshot or

Average

(Thermistor)

USDA

 

 

 

 

 

 

Sensor Format

1 or 2 byte

1 byte

 

 

 

Sensor

Refer to section

2 sensors

Configuration

3.3.5.f.

 

Logging Interval

15, 30, 60 or

60 minutes

120 minutes

 

 

Configuration cards are available thru CTD Replacement Components Group.

The use of a programming card in the field should only occur under unusual circumstances, such as a physical component in the container unit is changed to a different component, resulting in a new configuration for the unit.

SECTION 3

3-25

T-268-07

Page 63
Image 63
Carrier 69NT40-511-199, 69NT40-521 manual DataCORDER Configuration, Setting Factory Default