E2017 | Timer Fail | Timer refresh failure. |
E2018 | Prog Timer | Programmable interval timer error. |
|
|
|
E2019 | Parity Error | Parity error. |
|
|
|
E201A | SIO Err | SIO failure. |
|
|
|
E201B | Kybd Controller | Keyboard controller failure. |
|
|
|
E201C | SMI Init | System management interrupt (SMI) initialization failure. |
|
|
|
E201D | Shutdown Test | BIOS shutdown test failure. |
|
|
|
E201E | POST Mem Test | BIOS POST memory test failure. |
|
|
|
E201F | DRAC Config | Dell remote access controller (DRAC) configuration failure. |
|
|
|
E2020 | CPU Config | CPU configuration failure. |
|
|
|
E2021 | Memory Population | Incorrect memory configuration. Memory population order |
|
| incorrect. |
|
|
|
E2022 | POST Fail | General failure after video. |
|
|
|
E2110 | MBE Crd # DIMM ## & | One of the DIMMs in the set implicated by "## & ##" has had a |
| ## | memory |
|
| the "Crd #" string is left out of the message. |
|
|
|
E2111 | SBE Log Disable Crd # | The system BIOS has disabled memory |
| DIMM ## | logging, and will not resume logging further SBEs until the |
|
| system is rebooted. "##" represents the DIMM implicated by the |
|
| BIOS. If no memory riser card is present, the "Crd #" string is |
|
| left out of the message. |
|
|
|
E2112 | Mem Spare Crd # DIMM | The system BIOS has spared the memory because it has |
| ## | determined that the memory had too many errors. "## & ##" |
|
| represents the DIMM pair implicated by the BIOS. If no |
|
| memory card is present, the "Crd #" string is left out of the |
|
| message. |
|
|
|
E2113 | Mem Mirror Crd # DIMM | The system BIOS has disabled memory mirroring because it has |
| ## & ## | determined that one half of the mirror has had too many errors. |
|
| "## & ##" represents the DIMM pair implicated by the BIOS. If |
|
| no memory card is present, the "Crd #" string is left out of the |
|
| message. |
|
|
|
E2118 | Fatal NB Mem CRC | One of the connections in the Fully Buffered DIMM (FBD) |
|
| memory subsystem link on the Northbound side has failed. |
|
|
|
E2119 | Fatal SB Mem CRC | One of the connections in the FBD memory subsystem link on |
|
| the Southbound side has failed. |
|
|
|
I1910 | Intrusion | System cover has been removed. |
|
|
|
I1911 | >3 ERRs Chk Log | LCD overflow message. |
|
| A maximum of three error messages can display sequentially on |
|
| the LCD. The fourth message displays as the standard overflow |
|
| message. |
|
|
|
I1912 | SEL Full | System Event Log is full of events, and is unable to log any |
|
| more events. |
|
|
|
W1228 | ROMB Batt < 24hr | Warns predictively that the RAID battery has less than 24 hours |
|
| of charge left. |
|
|
|
InfraStruXure Central Installation Manual | 23 |