APC AP9470, AP9475, AP9465 installation manual Timer refresh failure

Page 27

E2017

Timer Fail

Timer refresh failure.

E2018

Prog Timer

Programmable interval timer error.

 

 

 

E2019

Parity Error

Parity error.

 

 

 

E201A

SIO Err

SIO failure.

 

 

 

E201B

Kybd Controller

Keyboard controller failure.

 

 

 

E201C

SMI Init

System management interrupt (SMI) initialization failure.

 

 

 

E201D

Shutdown Test

BIOS shutdown test failure.

 

 

 

E201E

POST Mem Test

BIOS POST memory test failure.

 

 

 

E201F

DRAC Config

Dell remote access controller (DRAC) configuration failure.

 

 

 

E2020

CPU Config

CPU configuration failure.

 

 

 

E2021

Memory Population

Incorrect memory configuration. Memory population order

 

 

incorrect.

 

 

 

E2022

POST Fail

General failure after video.

 

 

 

E2110

MBE Crd # DIMM ## &

One of the DIMMs in the set implicated by "## & ##" has had a

 

##

memory multi-bit error (MBE). If no memory card is present,

 

 

the "Crd #" string is left out of the message.

 

 

 

E2111

SBE Log Disable Crd #

The system BIOS has disabled memory single-bit error (SBE)

 

DIMM ##

logging, and will not resume logging further SBEs until the

 

 

system is rebooted. "##" represents the DIMM implicated by the

 

 

BIOS. If no memory riser card is present, the "Crd #" string is

 

 

left out of the message.

 

 

 

E2112

Mem Spare Crd # DIMM

The system BIOS has spared the memory because it has

 

##

determined that the memory had too many errors. "## & ##"

 

 

represents the DIMM pair implicated by the BIOS. If no

 

 

memory card is present, the "Crd #" string is left out of the

 

 

message.

 

 

 

E2113

Mem Mirror Crd # DIMM

The system BIOS has disabled memory mirroring because it has

 

## & ##

determined that one half of the mirror has had too many errors.

 

 

"## & ##" represents the DIMM pair implicated by the BIOS. If

 

 

no memory card is present, the "Crd #" string is left out of the

 

 

message.

 

 

 

E2118

Fatal NB Mem CRC

One of the connections in the Fully Buffered DIMM (FBD)

 

 

memory subsystem link on the Northbound side has failed.

 

 

 

E2119

Fatal SB Mem CRC

One of the connections in the FBD memory subsystem link on

 

 

the Southbound side has failed.

 

 

 

I1910

Intrusion

System cover has been removed.

 

 

 

I1911

>3 ERRs Chk Log

LCD overflow message.

 

 

A maximum of three error messages can display sequentially on

 

 

the LCD. The fourth message displays as the standard overflow

 

 

message.

 

 

 

I1912

SEL Full

System Event Log is full of events, and is unable to log any

 

 

more events.

 

 

 

W1228

ROMB Batt < 24hr

Warns predictively that the RAID battery has less than 24 hours

 

 

of charge left.

 

 

 

InfraStruXure Central Installation Manual

23

Image 27
Contents Installation Manual 동봉된 CD 안에 한국어 매뉴얼이 있습니다 Contents Appendix B Diagnostic Messages Overview Product DescriptionSafety Rack-mounting safetyEquipment containing a battery Installation Installation InstructionsBefore You Begin Select a location within the rack RapidRails Rack Kit ContentsInstallation Tasks Remove the rack doorsInstall the RapidRails slide assemblies Install the system in the rack Network overview Set up the Private LANCommunication Connection Replace the rack doorsInstall and route data cables alternative routing Connect the InfraStruXure Central server to your Private LAN Connect the InfraStruXure Central server to your Public LANInitial Configuration Configure the InfraStruXure Central ServerSystem and Web browser prerequisites Enable Remote Monitoring Product Information InfraStruXure Central Front PanelBasic model front ItemFunction Standard model frontEnterprise model front Basic model rear InfraStruXure Central rear panelStandard Model rear Enterprise Model rear InfraStruXure Central server SpecificationsAppendix a LED Error Codes Error Code ListingOverview InfraStruXure Central Installation Manual Message Listing Appendix B Diagnostic MessagesPower supply voltage is out of acceptable range specified Timer refresh failure Warranties and Policies Two-Year Factory WarrantyTerms of warranty Non-transferable warranty ExclusionsExamples of life-support devices Warranty claimsLife Support Policy General policyInfraStruXure Central Installation Manual Page 06/2008 990-3321-001