Appendix B: Diagnostic Messages
Message Listing
Overview
The system's control panel LCD provides status messages to signify when the system is operating correctly or when the system needs attention.
The LCD lights blue to indicate a normal operating condition, and lights amber to indicate an error condition. The LCD scrolls a message that includes a status code followed by descriptive text..
The following table lists the potential error messages along with a short description of the condition described by the message.
Code | Text | Causes |
|
|
|
N/A | SYSTEM NAME | The SYSTEM NAME displays under the following conditions: |
|
| • The system is turned on. |
|
| • The power is off and active POST errors are displayed. |
|
|
|
E1000 | FAILSAFE, Call | Contact APC Customer Support at a number on the back cover |
| Support | of this manual |
|
|
|
E1114 | Temp Ambient | Ambient system temperature is out of acceptable range. |
|
|
|
E1116 | Temp Memory | Memory has exceeded acceptable temperature and has been |
|
| disabled to prevent damage to the components. |
|
|
|
E12nn | xx PwrGd | Specified voltage regulator has failed. |
|
|
|
E1210 | CMOS Batt | CMOS battery is missing, or the voltage is out of acceptable |
|
| range. |
|
|
|
E1211 | ROMB Batt | RAID battery is either missing, bad, or unable to recharge due to |
|
| thermal issues. |
|
|
|
E1229 | CPU # VCORE | Processor # VCORE voltage regulator has failed. |
|
|
|
E1310 | RPM Fan ## | RPM of specified cooling fan is out of acceptable operating |
|
| range. |
|
|
|
E1313 | Fan Redundancy | The system is no longer |
|
| put the system at risk of |
|
|
|
E1410 | CPU # IERR | Specified microprocessor is reporting an internal error. |
|
|
|
E1414 | CPU # Thermtrip | Specified microprocessor is out of acceptable temperature range |
|
| and has halted operation. |
|
|
|
E1418 | CPU # Presence | Specified processor is missing or bad, and the system is in an |
|
| unsupported configuration. |
|
|
|
E141C | CPU Mismatch | Processors are in a configuration unsupported by APC. |
|
|
|
E141F | CPU Protocol | The system BIOS has reported a processor protocol error. |
|
|
|
E1420 | CPU Bus PERR | The system BIOS has reported a processor bus parity error. |
|
|
|
E1421 | CPU Init | The system BIOS has reported a processor initialization error. |
|
|
|
E1422 | CPU Machine Chk | The system BIOS has reported a machine check error. |
|
|
|
E1610 | PS # Missing | No power is available from the specified power supply; |
|
| specified power supply is improperly installed or faulty. |
|
|
|
E1614 | PS # Status | No power is available from the specified power supply; |
|
| specified power supply is improperly installed or faulty. |
|
|
|
InfraStruXure Central Installation Manual | 21 |