| Field rotation. The direction of the field with respect to the | ||
| supply. |
|
|
| Values: | 0 = top of field toward top of supply | |
|
| 1 | = top of field toward left of supply |
|
| 2 | = top of field toward bottom of supply |
|
| 3 | = top of field toward right of supply |
HEIGHT | One to four digits for the bar code height in tenths of | ||
| millimeters. The value should be less than the length or width | ||
| of the supply. | ||
| Values: | ||
HR | (Human readable characters) One digit for the location of | ||
| human readable characters printed with a UPC or EAN bar | ||
| code. If no value is given, no human readable characters are | ||
| printed. |
|
|
| Values: | 0 = No human readable characters printed | |
|
| 1 | = Human readable printed above the bar code |
|
| 2 | = Human readable printed below the bar code |
NOTE: Always use the HR parameter to generate the human readable text for a UPC or EAN bar code. If you manually insert human readable text, the barcode may not print accurately.
Example B11,I,1,70,30,1,4,0,120,0 p
The bar code field number is B11, the field increases by 1 with successive tickets (IFLAG = I, increment value = 1). The field begins 7 millimeters from the bottom and 3 millimeters from the left edge of the print area. The bar code density is 6.63 characters per inch (density = 1, code 39), and Code 39 (4) is used. The top of the field points to the top of the supply (rotation
=0). The height of the bar code is 12 millimeters and no human readable characters appear with this bar code (0).
The following special restrictions apply to online bar codes:
UPCA | You must send a leading zero, 11 digits of |
| data and a check digit (13 digits total). |