3.1.2 Wiring

VDSL typically operates over 2-wire CAT-3 wiring; however, other categorized or uncategorized twisted-pair wiring will work although the performance will vary depending on the distance and cable characteristics. It is important that the wiring used does not have any open leads (also known as bridged taps or drop-lines) along its length because this will impact performance by degrading the signal.

3.1.3 Configuration & Setup

1.Log into the RuggedSwitch Operating System.

2.Highlight Ethernet Ports and press Enter.

3.Highlight Configure/View EoVDSL Parameters and press Enter. This will take you to the EoVDSL Parameters screen. Press Enter again.

4.Highlight Mode and press Enter.

5.Either press the Up or Down arrow to select either Master or Slave. Press Enter.

6.Press Control and A together to apply the changes.

Once configured as master and slave and connected together, the units will then attempt to achieve the maximum speed based on the line length and conditions. The unit’s link LED may flash on and off several times before settling on a final link speed and declaring the port up. Please see the Rugged Operating System (ROS) Software User Guide for detailed software configuration options.

3.1.4 Performance

On 24 American Wire Gauge (AWG) Polyethylene Insulated Cable (PIC) twisted-pair the following performance is typical:

Distance

Distance

Downstream/Upstream

Time to Achieve Port Up

[km]

[feet]

[Mbps]

[Seconds]

0.5

1600

35.00

15

0.6

2000

30.00

30

0.7

2300

25.00

45

0.8

3000

20.00

60

1.0

3300

15.00

75

1.3

4300

10.00

90

1.7

5600

5.00

105

2.0

6600

2.50

120

2.5

8200

1.00

135

Table 5 - Typical Performance on 24 AWG PIC twisted-pair

 

15

2007 RuggedCom Inc. All rights reserved

Rev101

Image 15
Contents Installation Guide RuggedSwitch RS900LTrademarks Table of Contents Table of Figures Feature Highlights Product OverviewFunctional Overview Front Panel Description Front Panel DescriptionBottom Panel Description Bottom Panel DescriptionDin Rail Mounting InstallationAC Power Supply Wiring and Grounding Power Supply Wiring and GroundingDC Power supply wiring and grounding diagram DC Power Supply Wiring and GroundingFailsafe Output Relay Failsafe Output WiringDielectric Strength Testing Dielectric Strength TestingRS232 Female DCE pin-out RS232 Console Port WiringEthernet Ports RJ11 Ethernet over Vdsl PortOverview Wiring Configuration & SetupPerformance  2007 RuggedCom Inc. All rights reserved Rev101 RJ45 port pin-out and LEDs RJ45 Ethernet Ports 2007 RuggedCom Inc. All rights reserved Rev101 Fiber Optic Ethernet Ports 100FX Mtrj connectorOperating Environment Technical SpecificationsPower Supply Specifications Failsafe Relay SpecificationsRJ45 Ethernet Port Specifications RJ11 Ethernet over Vdsl Port SpecificationsCommunication Standards Fiber Optic Ethernet Port SpecificationsParameter Value Mechanical SpecificationsIEC 61850-3 Type Tests Type TestsIEC Environmental Type Tests Ieee 1613 Type TestsWarranty