RuggedCom RS900L manual IEC 61850-3 Type Tests

Page 24

5 Type Tests

5.1 IEC 61850-3 Type Tests

 

Test

 

 

Description

 

 

Test Levels

 

 

Severity

 

 

 

 

 

 

 

 

Levels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 61000-4-2

 

ESD

Enclosure Contact

 

+/- 8kV

4

 

 

 

 

 

 

 

 

 

 

 

 

 

Enclosure Air

 

+/- 15kV

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 61000-4-3

 

Radiated RFI

Enclosure ports

 

20 V/m

 

x

 

 

 

 

 

Signal ports

 

+/- 4kV @ 2.5kHz

 

x

 

 

 

 

 

 

 

 

 

 

 

IEC 61000-4-4

 

Burst (Fast

D.C. Power ports

 

+/- 4kV

4

 

 

 

Transient)

A.C. Power ports

 

+/- 4kV

4

 

 

 

 

 

 

 

 

 

 

 

 

Earth ground ports

 

+/- 4kV

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal ports

 

+/- 4kV line-to-earth, +/- 2kV line-to-

4

 

 

 

 

 

 

 

line

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 61000-4-5

 

Surge

D.C. Power ports

 

+/- 2kV line-to-earth, +/- 1kV line-to-

3

 

 

 

 

line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.C. Power ports

 

+/- 4kV line-to-earth, +/- 2kV line-to-

4

 

 

 

 

 

 

 

line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal ports

 

10V

3

 

 

 

 

 

 

 

 

 

 

 

 

IEC 61000-4-6

 

Induced

D.C Power ports

 

10V

3

 

 

 

(Conducted) RFI

A.C. Power ports

 

10V

3

 

 

 

 

 

 

 

 

 

 

 

 

Earth ground ports

 

10V

3

 

 

 

 

 

 

 

 

 

 

 

IEC 61000-4-8

 

Magnetic Field

Enclosure ports

 

40 A/m continuous, 1000 A/m for 1 s

 

N/A

 

 

 

 

 

D.C. Power ports

 

30% for 0.1s, 60% for 0.1s, 100% for

 

N/A

 

IEC 61000-4-29

 

 

 

0.05s

 

 

 

Voltage Dips &

 

 

 

 

 

 

 

 

 

 

 

 

 

30% for 1 period, 60% for 50 periods

 

N/A

 

 

 

 

Interrupts

 

 

 

 

 

IEC 61000-4-11

 

A.C. Power ports

 

100% for 5 periods, 100% for 50

 

N/A

 

 

 

 

 

 

 

 

 

 

 

periods 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal ports

 

2.5kV common, 1kV differential mode

3

 

 

 

 

 

 

 

@ 1MHz

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 61000-4-12

 

Damped

D.C. Power ports

 

2.5kV common, 1kV differential mode

3

 

 

 

Oscillatory

 

@ 1MHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.C. Power ports

 

2.5kV common, 1kV differential mode

3

 

 

 

 

 

 

 

@ 1MHz

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 61000-4-16

 

Mains Frequency

Signal ports

 

30V Continuous, 300V for 1s

4

 

 

 

Voltage

D.C. Power ports

 

30V Continuous, 300V for 1s

4

 

 

 

 

 

 

 

 

IEC 61000-4-17

 

Ripple on D.C.

D.C. Power ports

10%

 

3

 

 

 

Power Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal ports

 

2kV AC (Fail-Safe Relay output)

 

N/A

 

IEC 60255-5

 

Dielectric Strength

D.C. Power ports

 

2kV AC

 

N/A

 

 

 

 

 

A.C. Power ports

 

2kV AC

 

N/A

 

 

 

 

 

Signal ports

 

5kV (Fail-Safe Relay output)

 

N/A

 

IEC 60255-5

 

H.V. Impulse

D.C. Power ports

 

5kV

 

N/A

 

 

 

 

 

A.C. Power ports

 

5kV

 

N/A

Table 16 - IEC 61850-3 Type Tests

 

24

2007 RuggedCom Inc. All rights reserved

Rev101

Image 24
Contents RuggedSwitch RS900L Installation GuideTrademarks Table of Contents Table of Figures Feature Highlights Product OverviewFunctional Overview Front Panel Description Front Panel DescriptionBottom Panel Description Bottom Panel DescriptionInstallation Din Rail MountingPower Supply Wiring and Grounding AC Power Supply Wiring and GroundingDC Power Supply Wiring and Grounding DC Power supply wiring and grounding diagramFailsafe Output Wiring Failsafe Output RelayDielectric Strength Testing Dielectric Strength TestingRS232 Console Port Wiring RS232 Female DCE pin-outEthernet Ports RJ11 Ethernet over Vdsl PortOverview Wiring Configuration & SetupPerformance  2007 RuggedCom Inc. All rights reserved Rev101 RJ45 Ethernet Ports RJ45 port pin-out and LEDs 2007 RuggedCom Inc. All rights reserved Rev101 100FX Mtrj connector Fiber Optic Ethernet PortsTechnical Specifications Power Supply SpecificationsFailsafe Relay Specifications Operating EnvironmentRJ11 Ethernet over Vdsl Port Specifications RJ45 Ethernet Port SpecificationsFiber Optic Ethernet Port Specifications Communication StandardsMechanical Specifications Parameter ValueType Tests IEC 61850-3 Type TestsIeee 1613 Type Tests IEC Environmental Type TestsWarranty