RuggedCom RS900L manual Ieee 1613 Type Tests, IEC Environmental Type Tests

Page 25

5.2 IEEE 1613 Type Tests

 

Test

 

 

Description

 

Test Levels

 

IEEE C37.90.3

 

ESD

 

Enclosure Contact

 

+/- 8kV

 

 

 

Enclosure Air

 

+/- 15kV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IEEE C37.90.2

 

Radiated RFI

 

Enclosure ports

 

35 V/m

 

 

 

 

 

Signal ports

 

+/- 4kV @ 2.5kHz

 

IEEE C37.90.1

 

Fast Transient

 

D.C. Power ports

 

+/- 4kV

 

 

 

 

 

 

 

 

 

A.C. Power ports

 

+/- 4kV

 

 

 

 

 

 

 

 

 

 

 

Earth ground ports

 

+/- 4kV

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal ports

 

2.5kV common mode @ 1MHz

 

IEEE C37.90.1

 

Oscillatory

 

 

 

 

 

 

 

D.C. Power ports

 

2.5kV common & differential mode @ 1MHz

 

 

 

 

 

A.C. Power ports

 

2.5kV common & differential mode @ 1MHz

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal ports

 

5 kV (Failsafe Relay)

 

IEEE C37.90

 

H.V. Impulse

 

D.C. Power ports

 

5 kV

 

 

 

 

 

A.C. Power ports

 

5 kV

 

 

 

Dielectric

 

Signal ports

 

2kV AC(Failsafe Relay)

 

IEEE C37.90

 

 

 

 

 

 

 

 

D.C. Power ports

 

2kV AC

 

 

Strength

 

 

 

 

 

 

A.C. Power ports

 

2kV AC

 

 

 

 

 

 

Table 17 - IEEE 1613 Type Tests

NOTE:

If the unit contains copper ports the IEEE 1613 conformance is Class 1 (During disturbance errors may occur but recovery is automatic).

If the unit contains all fiber ports the IEEE 1613 conformance is Class 2 (During disturbance no errors will occur).

5.3 IEC Environmental Type Tests

Test

Description

Test Levels

 

 

Severity

Levels

IEC 60068-2-1

IEC 60068-2-2

IEC 60068-2-30

IEC 60255-21-1

Cold Temperature

Dry Heat

Humidity (Damp Heat,

Cyclic)

Vibration

Test Ad

-40 deg. C, 16 Hours

Test Bd

+85 deg. C, 16 Hours

 

 

Test Db

95% (non-condensing), 55°C, 6 cycles

Tests Fc

2g @ (10-150) Hz

N/A

N/A

N/A

Class 2

IEC 60255-21-2

Shock

Tests Ea

30g @ 11 ms

Table 18 - Environmental Type Tests

Class 2

 

25

2007 RuggedCom Inc. All rights reserved

Rev101

Image 25
Contents Installation Guide RuggedSwitch RS900LTrademarks Table of Contents Table of Figures Product Overview Feature HighlightsFunctional Overview Front Panel Description Front Panel DescriptionBottom Panel Description Bottom Panel DescriptionDin Rail Mounting InstallationAC Power Supply Wiring and Grounding Power Supply Wiring and GroundingDC Power supply wiring and grounding diagram DC Power Supply Wiring and GroundingFailsafe Output Relay Failsafe Output WiringDielectric Strength Testing Dielectric Strength TestingRS232 Female DCE pin-out RS232 Console Port WiringRJ11 Ethernet over Vdsl Port Ethernet PortsOverview Configuration & Setup WiringPerformance  2007 RuggedCom Inc. All rights reserved Rev101 RJ45 port pin-out and LEDs RJ45 Ethernet Ports 2007 RuggedCom Inc. All rights reserved Rev101 Fiber Optic Ethernet Ports 100FX Mtrj connectorPower Supply Specifications Technical SpecificationsFailsafe Relay Specifications Operating EnvironmentRJ45 Ethernet Port Specifications RJ11 Ethernet over Vdsl Port SpecificationsCommunication Standards Fiber Optic Ethernet Port SpecificationsParameter Value Mechanical SpecificationsIEC 61850-3 Type Tests Type TestsIEC Environmental Type Tests Ieee 1613 Type TestsWarranty