4 | Technical Specifications |
| ||
4.1 | Operating Environment |
|
| |
|
|
|
|
|
| Parameter |
| Range | Comments |
|
|
|
| Ambient Temperature as |
Ambient Operating Temperature |
| measured from a 30 cm radius | ||
| surrounding the center of the | |||
|
|
|
| |
|
|
|
| enclosure. |
Ambient Storage Temperature |
|
| ||
Ambient Relative Humidity |
| 5% to 95% |
Table 8 - Operating Environment
4.2 Power Supply Specifications
Power Supply Type
12 – 24 VDC
24VDC
48VDC
HI (125/250 VDC) 1 HI (110/230 VAC) 1
Minimum
Input
10VDC
18VDC
36VDC
88VDC
85VAC
Maximum
Input
36VDC
36VDC
72VDC
300VDC
265VAC
Fuse
Rating
3.15(T)
3.15(T)
3.15(T)
3.15(T)
Isolation
1.5kV DC
1.5kV DC
1.5kV DC
4 kV AC 5.5
kV DC
Maximum Power
Consumption
10W
Table 9 - Power Supply Specifications
NOTES:
1.This is the same power supply for both AC and DC.
2.(F) Denotes
3.For continued protection against risk of fire, replace only with same type and rating of fuse.
4.3 Failsafe Relay Specifications
Load Circuit
MAX operating Voltage
MAX operating Current
Isolation (between coil and contacts)
| SELV | |
|
|
|
30VDC |
| 30 VAC |
1A |
| 0.5A |
|
|
|
|
| 1800 Vrms |
|
|
|
80VDC
0.3A
Table 10 - Failsafe Relay Specifications
| 20 |
2007 RuggedCom Inc. All rights reserved | Rev101 |