Rose electronic Professional Series manual Ultraview PRO Installation and Operations Manual

Page 21

Expansion

If your system consists of cascaded units, the expansion section of the Configure System menu must be properly configured to provide the needed information to manage the slave units.

It is recommended that all slave units have the same number of CPU ports. To change the “Maximum computers”, “Expansion width”, and “Expansion units”, use the up/down arrow keys and select the item and press enter. An input box will display for a new value.

Maximum computers

This setting configures the total number of computers that are connected and provides a wrap around value for scanning and the plus/minus commands. Switching commands are validated against this value for a valid port number. The “Maximum computers” value is the Expansion width value times the number of slave units plus the CPU ports on the master unit that are not used for expansion. Enter the number of connected computers and press enter. Valid entries are 2 to 256.

Expansion width

The “Expansion width” setting determines how many computers are connected to a slave unit. If the slave units are 4 port units, the width value would be 4. If they are 8 port units, the expansion width value would be 8. If the expansion units are a mixture of 4, 8, and/or 16 port units, the “Expansion width” value is the number of CPU ports on the expansion unit with the greatest number of ports.

Expansion units

The “Expansion units” setting is the number of slave units that are connected to the master unit. This value determines which computer number is associated with which physical connector.

If no expansion units are used, this number should be set to zero. In the example in Figure 4, the “Expansion units” setting to enter would be 2.

Scan settings

The scan settings section determines the amount of time in seconds that a computer’s video is displayed before automatically switching to the next sequential computer. The scan mode can be turned on or off and set to automatically scan the computers when the UltraView Pro is powered up.

Scan time (seconds)

ULTRAVIEW PRO INSTALLATION AND OPERATIONS MANUAL

15

 

 

Image 21
Contents Installation and Operations Manual Page Copyright  Rose Electronics 1990-2002. All rights reserved Limited WarrantyFCC/IC STATEMENTS, EU Declaration of Conformity Table of Contents Appendices TablesIntroduction DisclaimerIntroduction / System overview Package contents FeaturesCompatibility System overviewRose Electronics web site KVM stationCPU connection Cascading UnitsMenu system UltraView Pro models ModelsMouse UltraView Pro models rearUltraView Pro Cables CablesUltraView Pro to KVM station cable UltraView Pro to CPU cablesInstallation single unit InstallationConnecting the keyboard, video monitor, and mouse Apply power to UltraView ProConnecting the computers UltraView Pro to CPUs Installation Cascading unitsCascading units Slave unit installationUltraview PRO Installation and Operations Manual Main configuration menu Configuration MenusConfigure system menu Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Configure computer menu USB-PC Configure overlay Configure overlayUltraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Configure security Ultraview PRO Installation and Operations Manual Selecting a computer OperationKeyboard commands Keyboard CommandsType Keyboard command usage Reset to factory defaultsRackmounting Firmware update RS232 PortSerial Port RS232 Ultraview PRO Installation and Operations Manual Good Troubleshooting TroubleshootingUltraview PRO Installation and Operations Manual Service Information Service and MaintenanceMaintenance and Repair Technical SupportSafety SafetySafety and EMC Regulatory Statements Ultraview PRO Installation and Operations Manual YES AppendicesKIT-ATRX Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Page Stancliff Road Houston, Texas Phone 281