Configuration password

To assign a “Configuration password”, select it from the “Configure security” menu and press enter. An input box will appear. Type in the desired configuration password (case sensitive, 8 chars/max) and press enter. A confirmation box will display, re-type the password and press enter. When the password is saved, the next time the configuration menu is called up (<Ctrl>, F12), this password must be entered.

Access password

This feature is used to restrict unauthorized access to the connected computers. To assign an access password, select it from the menu and press enter. Enter this password the same way as you entered the configuration password. When the UltraView Pro is powered on or if you disconnect from a computer, a login box will display requesting the access password.

Access time (minutes)

The access time setting is used to automatically log out of a switch after the set time period. When there is no keyboard or mouse activity for this time setting, the user is automatically logged out. To change this value, select it from the menu and hit enter. An input box will display for a new access time value. Enter the new time in minutes and hit enter. Valid times are 1 to 999 minutes.

Logging off the system

To log off the system and lock the keyboard enter <Ctrl> and the L key to disconnect from the switch. To gain access to the connected computers, an access password must be entered if one has been assigned.

Resetting the passwords

The passwords can be reset if they are ever forgotten. To reset them, first turn off the UltraView Pro and disconnect the power cord or power adapter. Carefully remove the top chassis cover exposing the PCB. Put a jumper on the two pins labeled “Password reset jumper” and power on the switch. Call up the configure security menu and enter a new configuration password, access password and access time. Press <Esc> to return to the main menu. Select “Exit” and press enter. You will be prompted to save the changes. Select “YES” and press enter. The new password settings will be saved in flash memory. Next, turn off the UltraView Pro and remove the installed jumper. Replace the top chassis cover and power the switch back up. The new passwords will be active after power is applied.

ULTRAVIEW PRO INSTALLATION AND OPERATIONS MANUAL

25

 

 

Image 31
Contents Installation and Operations Manual Page Copyright  Rose Electronics 1990-2002. All rights reserved Limited WarrantyFCC/IC STATEMENTS, EU Declaration of Conformity Table of Contents Appendices TablesDisclaimer IntroductionIntroduction / System overview Package contents FeaturesKVM station System overviewCompatibility Rose Electronics web siteCascading Units CPU connectionMenu system UltraView Pro models ModelsMouse UltraView Pro models rearUltraView Pro to CPU cables CablesUltraView Pro Cables UltraView Pro to KVM station cableApply power to UltraView Pro InstallationInstallation single unit Connecting the keyboard, video monitor, and mouseConnecting the computers UltraView Pro to CPUs Installation Cascading unitsCascading units Slave unit installationUltraview PRO Installation and Operations Manual Main configuration menu Configuration MenusConfigure system menu Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Configure computer menu USB-PC Configure overlay Configure overlayUltraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Configure security Ultraview PRO Installation and Operations Manual Selecting a computer OperationKeyboard commands Keyboard CommandsType Reset to factory defaults Keyboard command usageRackmounting RS232 Port Firmware updateSerial Port RS232 Ultraview PRO Installation and Operations Manual Good Troubleshooting TroubleshootingUltraview PRO Installation and Operations Manual Technical Support Service and MaintenanceService Information Maintenance and RepairSafety SafetySafety and EMC Regulatory Statements Ultraview PRO Installation and Operations Manual YES AppendicesKIT-ATRX Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Page Stancliff Road Houston, Texas Phone 281