To update the UltraView Pro’s firmware, first download the latest revision from Rose Electronics web site and save it to a
Method 1 – Using a communication program
1.Press both the - and + switches on the front panel and power on the UltraView Pro. LED 1 will light indicating the unit is ready to accept the upgrade file at 9600 baud. To use 57600 baud rate, press the + switch and LED 1 will turn off and LED 4 will light.
2.Run your communication program. Set the baud rate to the correct rate and put the program in direct connect mode. When the - or + switch is pressed, you should see the message: ”Waiting for file at 9600 or 57600 baud.”
3.Send the file to the unit using a simple ASCII text file protocol. While the file is being sent, periods are sent to indicate the file copy progress. Once the file has been sent, you should see the following message:
”Receive successful” ”Hit space to program”
4.Hit the space bar to start programming the flash memory. The programming and verifying progress is indicated by sending periods. You should see the following message: ”Programming flash”
…………………
”Verifying flash”
…………………
”Verify successful” ”Hit enter to boot”
5.Hit enter and the UltraView Pro will
6.Hit the enter key to continue. The UltraView Pro is now operational with the new firmware update.
If the upgrade is not successful, you will see one of the following error messages:
Checksum error or Record error or Data error
Receive failed Try again Y/N?
ULTRAVIEW PRO INSTALLATION AND OPERATIONS MANUAL | 31 |
|
|