Rose electronic 4X, 8X, 16X manual Configure system System settings

Page 31

Configure system

Configure system

System settings

 

 

Configure password

 

********

 

 

 

 

Starting computer number

 

1

 

 

 

 

Maximum computers

 

64

 

 

 

 

 

 

 

 

 

 

 

Keyboard settings

 

 

 

 

 

 

PC keyboard rate (char./sec)

 

20

 

 

 

 

PC keyboard delay

 

Fast

 

 

 

 

Sun keyboard language

 

US

 

 

 

 

 

 

 

 

 

 

 

Appearance

 

 

 

 

 

 

Menu color scheme

 

Night sky

 

 

 

 

Screen saver

 

Weaving

 

 

 

 

Screen saver time (seconds)

 

1800

 

 

 

 

Background color

 

Cyan

 

 

 

 

Text color

 

Black

 

 

 

 

Position

 

X = 25 Y = 45

 

 

 

 

 

 

 

 

 

 

 

Fadeout (seconds)

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Password to configure unit

Figure 18. Configure system menu

Selecting “System” from the main menu displays the “Configure system”” menu. This menu allows you to configure the System, KVM keyboard, and Appearance settings. Each “Configure system” section is explained below.

“System settings”

Configure password (Default: no password)

The “Configure password” selection is used to add a new or change an existing configuration password. This password prevents unauthorized access to the configuration menus. Passwords are case sensitive, 8 characters max.

To create or change a password, select “Configure password” and press [Enter]. An input box will display to enter the password. Type in the password and press [Enter]. Whenever the menu system is called up, (Left Ctrl, F12) this password must be entered to gain access to the configuration menus.

See Appendix G for instructions on resetting a forgotten configuration password.

Starting computer number (Default: 1)

The “Starting computer” number defines to the system the first CPU port number for a particular UltraMatrix switch that is configured in an expanded topology.

Switch #1’s starting computer number is always 1.

Switch #2’s starting computer number is the total RS232 ports on Unit #1 times 4 + 1.

Switch #3’s starting computer number is the total RS232 ports on Unit #1 and Unit #2 times 4 + 1 and so forth.

To enter the “Starting computer” number, use the up/down arrow keys and select “Starting computer number” and press [Enter]. An input box will display for a new starting computer number. Enter the new number and press [Enter].

ULTRAMATRIX “UMX” SERIES INSTALLATION AND OPERATIONS MANUAL

25

Image 31
Contents Ultramatrix 4X, 8X, Installation and Operations Manual Limited Warranty FCC/IC STATEMENTS, EU Declaration of Conformity Table of Contents Appendices TablesPage Introduction IntroductionDisclaimer About this manualFeatures Ultramatrix UMX Series Installation and Operations Manual UltraMatrix models ModelsSystem overview OverviewIN1 IN3 Ultramatrix UMX Series Installation and Operations Manual Site planning Site PlanningSwitch installation Single unit InstallationUltramatrix UMX Series Installation and Operations Manual Multi-switch installation BUS topology Multi-switch installation GeneralUltramatrix UMX Series Installation and Operations Manual UM4 BUS topology Multi-switch installation Ring topology Ultramatrix UMX Series Installation and Operations Manual UM4 Ring topology Multi-switch installation Split BUS topology UM4 Split BUS Multi-switch installation Staggered BUS topology Ultramatrix UMX Series Installation and Operations Manual UM4 Staggered BUS UltraMatrix Configuration MenusKVM Menu SystemConfigure system System settings Ultramatrix UMX Series Installation and Operations Manual Ultramatrix UMX Series Installation and Operations Manual PC2 Ultramatrix UMX Series Installation and Operations Manual Bus KVM name Resolution Start User KVM station 640x480@60 Ultramatrix UMX Series Installation and Operations Manual Configure user Configure User Configure Profile Ultramatrix UMX Series Installation and Operations Manual Computer Group Main Menu Configure System Computer KVM CPU Configure System Computer User operating instructions OperationLogin Control Room Serial port usage RS232 Serial PortUM-HyperTerminal Ultramatrix UMX Series Installation and Operations Manual Ultramatrix UMX Series Installation and Operations Manual Switching using the serial port Serial device support Serial Device SupportService Information ServiceSafety SafetySafety and EMC Regulatory Statements Troubleshooting TroubleshootingUltramatrix UMX Series Installation and Operations Manual Appendices UM4 UM8 VGA HD15 MAC ADB KM CPU Ultramatrix UMX Series Installation and Operations Manual Ultramatrix UMX Series Installation and Operations Manual Message Description Ultramatrix UMX Series Installation and Operations Manual Ultramatrix UMX Series Installation and Operations Manual Page Stancliff Road Phone 281 Houston, Texas