Powerware 30-160kVA operation manual Inspecting and Unpacking the Maintenance Bypass Module

Page 11

Inspecting and Unpacking the Maintenance Bypass Module

The first task in preparing for installation of the MBM is inspecting and unpacking the unit. The MBM arrives covered with protective packaging material as shown in Figure 3.

OUTER

PACKAGING

LAMINATED PLYWOOD

AND POLYFOAM SKIDS

Figure 3. MBM as Shipped, with Outer Packaging and Pallet

Powerware 9315 Maintenance Bypass Module 30---160kVA

7

164201177 Rev. C 041500

 

Image 11
Contents Maintenance Bypass Module 30-160kVA Important Safety Instructions Table of Contents List of Figures Typical Power Wiring Terminations of UPS ModuleIntroduction Conventions Used in This Manual Using This ManualGetting Help For More InformationThis Page Intentionally Left Blank Getting Started Environmental Considerations Creating an Installation PlanPreparing for Wiring the Maintenance Bypass Module Preparing the SiteMBM as Shipped, with Outer Packaging and Pallet Inspecting and Unpacking the Maintenance Bypass ModuleDo not tilt unit more than 10 degrees from vertical Unloading the MBM from the Pallet Detail of Shipping Supports Installing and Wiring Maintenance Bypass Module Maintenance Bypass Module UPS Module 30-160kVA UPS Shown Line and Load Wiring This Page Intentionally Left Blank Maintenance Bypass Module Operation Maintenance Bypass Module OperationMBM Operation Without Kirk Key Interlocks From UPS Bypass to Maintenance BypassMBM Transfer Sequences MBM Operation With Kirk Key Interlocks OptionalKirk Key Solenoid Release Unit Skru From Maintenance Bypass to UPS Bypass Short Circuits MaintenanceMaintenance Bypass Module Diagrams Refer to -- Maintaining the UPS System of the PowerwareThis Page Intentionally Left Blank Appendix a --- Customer Information Lagging PF load Basic unit rating atMBM 30---160kVA, 480480VAC/600600VAC MBM 30---160kVA, 208208VAC Installation NotesMBM 50---160KVA, 380380VAC, 400400VAC, 415415VAC 480208VAC, 600208VAC, 208208VAC, 480480VAC Table B. Circuit Breaker Requirements for Powerware80KVA MBM Table C-- 1. Power Cable TerminationsSee Fi g Twisted Pair164201177---2 Interior Components Description Typical MBM CabinetTOP View Bottom View Description Typical UPS System with MBM 30---160kVA UPS System with MBM600600VAC, 400400VAC Oneline -- 30-160kVA, RT, 480480VAC480208VAC, 600208VAC Oneline -- 30-160kVA, RTDescription Oneline -- 30-160kVA, RT, 208208VAC 164201177---7 Oneline -- 30-160kVA, PARALLEL, 480480VACOneline -- 30-160kVA, Parallel Oneline -- 30-160kVA, PARALLEL, 208208VAC Description Line UP and Match Arrangement #1 Line UP and Match Arrangement #1Description Line UP and Match Arrangement #2 Line UP and Match Arrangement #2Description Line UP and Match Arrangement #3 Line UP and Match Arrangment Notes This Page Intentionally Left Blank

30-160kVA specifications

The Powerware 30-160kVA is an advanced uninterruptible power supply (UPS) designed to meet the demands of medium to large-scale facilities requiring reliable power protection. This UPS series is celebrated for its robust performance, comprehensive features, and innovative technologies, making it a standout choice for businesses looking to ensure continuous operation without power disruptions.

One of the defining characteristics of the Powerware 30-160kVA series is its high efficiency. The UPS provides exceptional energy savings and operates at up to 96% efficiency in double conversion mode and even higher in ECO mode. This efficiency translates to reduced operational costs and a smaller carbon footprint, which is increasingly important in today's environmentally conscious business landscape.

Another key feature of this UPS is its modular architecture, allowing for flexible scalability. Users can easily configure the system to meet their specific power requirements and can scale up or down as per their needs. This modularity minimizes downtime and provides an adaptable solution that grows alongside the business.

The Powerware 30-160kVA also utilizes advanced battery management technology. This feature enhances battery life and ensures the highest level of redundancy. The smart battery management system performs regular self-tests, identifying weaker cells and optimizing charging and discharging cycles. This helps to guarantee that the UPS is always ready to provide backup power when needed.

Moreover, this UPS series has a user-friendly interface, making monitoring and control straightforward. The LCD display provides real-time information regarding operational status, alarms, and system performance, empowering users to quickly respond to any anomalies.

In terms of connectivity and integration, the Powerware 30-160kVA supports multiple communication protocols. This includes options for SNMP and Modbus, facilitating easy integration with existing infrastructure and allowing for remote management.

In summary, the Powerware 30-160kVA series is designed for businesses seeking reliability, efficiency, and flexibility in power management. Its advanced technology, high efficiency, modular design, and user-friendly features make it an ideal choice for data centers, telecommunications, and various critical applications where uptime and power quality are paramount. This UPS not only safeguards equipment but also contributes to energy cost savings, making it an essential investment for organizations focused on operational resilience.