Powerware 30-160kVA operation manual Detail of Shipping Supports

Page 14

DOOR

 

 

 

REAR

POLYFOAM

 

 

 

 

 

 

SUPPORT

SKID

2

FRONT

SIDE

 

 

2

 

 

SUPPORT

SUPPORT

1

 

 

 

 

FLOOR

 

 

 

 

PROTECTOR

 

 

 

 

(4 PLACES)

 

 

 

 

 

 

 

 

1

 

 

 

 

POLYFOAM

 

 

JACKING BOLT

 

SKID

 

(USE FRONT AND REAR)

1

 

 

 

 

 

Figure 4. Detail of Shipping Supports

6.Carefully and evenly lower the MBM by turning each jacking bolt counterclockwise in sequence no more than two full turns each (maximum) until the supports contact the floor, and the module is no longer supported by the jacking bolts.

7.When the module is resting on the floor, remove the jacking bolts. Discard or recycle them in a responsible manner.

8.Remove the hardware labeled “2” in Figure 4, holding the front, rear and side supports to the module base (14 places). Discard or recycle the hardware and support brackets in a responsible manner.

9.Install the doors removed in step 1. The MBM is now ready to be rolled to its final location.

10

Powerware 9315 Maintenance Bypass Module 30-160kVA

 

164201177 Rev. C 041500

Image 14
Contents Maintenance Bypass Module 30-160kVA Important Safety Instructions Table of Contents Typical Power Wiring Terminations of UPS Module List of FiguresIntroduction Using This Manual Conventions Used in This ManualFor More Information Getting HelpThis Page Intentionally Left Blank Getting Started Preparing the Site Creating an Installation PlanPreparing for Wiring the Maintenance Bypass Module Environmental ConsiderationsInspecting and Unpacking the Maintenance Bypass Module MBM as Shipped, with Outer Packaging and PalletDo not tilt unit more than 10 degrees from vertical Unloading the MBM from the Pallet Detail of Shipping Supports Installing and Wiring Maintenance Bypass Module Maintenance Bypass Module UPS Module 30-160kVA UPS Shown Line and Load Wiring This Page Intentionally Left Blank Maintenance Bypass Module Operation Maintenance Bypass Module OperationFrom UPS Bypass to Maintenance Bypass MBM Operation Without Kirk Key InterlocksMBM Transfer Sequences MBM Operation With Kirk Key Interlocks OptionalKirk Key Solenoid Release Unit Skru From Maintenance Bypass to UPS Bypass Refer to -- Maintaining the UPS System of the Powerware MaintenanceMaintenance Bypass Module Diagrams Short CircuitsThis Page Intentionally Left Blank Appendix a --- Customer Information Basic unit rating at Lagging PF loadMBM 30---160kVA, 480480VAC/600600VAC Installation Notes MBM 30---160kVA, 208208VACMBM 50---160KVA, 380380VAC, 400400VAC, 415415VAC Table B. Circuit Breaker Requirements for Powerware 480208VAC, 600208VAC, 208208VAC, 480480VAC80KVA Table C-- 1. Power Cable Terminations MBMTwisted Pair See Fi g164201177---2 Description Typical MBM Cabinet Interior ComponentsTOP View Bottom View 30---160kVA UPS System with MBM Description Typical UPS System with MBMOneline -- 30-160kVA, RT, 480480VAC 600600VAC, 400400VACOneline -- 30-160kVA, RT 480208VAC, 600208VACDescription Oneline -- 30-160kVA, RT, 208208VAC Oneline -- 30-160kVA, PARALLEL, 480480VAC 164201177---7Oneline -- 30-160kVA, Parallel Oneline -- 30-160kVA, PARALLEL, 208208VAC Line UP and Match Arrangement #1 Description Line UP and Match Arrangement #1Line UP and Match Arrangement #2 Description Line UP and Match Arrangement #2Description Line UP and Match Arrangement #3 Line UP and Match Arrangment Notes This Page Intentionally Left Blank

30-160kVA specifications

The Powerware 30-160kVA is an advanced uninterruptible power supply (UPS) designed to meet the demands of medium to large-scale facilities requiring reliable power protection. This UPS series is celebrated for its robust performance, comprehensive features, and innovative technologies, making it a standout choice for businesses looking to ensure continuous operation without power disruptions.

One of the defining characteristics of the Powerware 30-160kVA series is its high efficiency. The UPS provides exceptional energy savings and operates at up to 96% efficiency in double conversion mode and even higher in ECO mode. This efficiency translates to reduced operational costs and a smaller carbon footprint, which is increasingly important in today's environmentally conscious business landscape.

Another key feature of this UPS is its modular architecture, allowing for flexible scalability. Users can easily configure the system to meet their specific power requirements and can scale up or down as per their needs. This modularity minimizes downtime and provides an adaptable solution that grows alongside the business.

The Powerware 30-160kVA also utilizes advanced battery management technology. This feature enhances battery life and ensures the highest level of redundancy. The smart battery management system performs regular self-tests, identifying weaker cells and optimizing charging and discharging cycles. This helps to guarantee that the UPS is always ready to provide backup power when needed.

Moreover, this UPS series has a user-friendly interface, making monitoring and control straightforward. The LCD display provides real-time information regarding operational status, alarms, and system performance, empowering users to quickly respond to any anomalies.

In terms of connectivity and integration, the Powerware 30-160kVA supports multiple communication protocols. This includes options for SNMP and Modbus, facilitating easy integration with existing infrastructure and allowing for remote management.

In summary, the Powerware 30-160kVA series is designed for businesses seeking reliability, efficiency, and flexibility in power management. Its advanced technology, high efficiency, modular design, and user-friendly features make it an ideal choice for data centers, telecommunications, and various critical applications where uptime and power quality are paramount. This UPS not only safeguards equipment but also contributes to energy cost savings, making it an essential investment for organizations focused on operational resilience.