Powerware 9335 operation manual Limited Factory Warranty for THREE-PHASE Powerware Products

Page 99

LIMITED FACTORY WARRANTY FOR THREE-PHASE POWERWARE PRODUCTS

Subject to the conditions herein, Invensys Powerware (Powerware ®) warrants solely, to the original end-user, the electronics (the “Unit”), and Powerware built battery cabinets, against defects in material and workmanship for the warranty period of 12 months, from the date of equipment start up, or 18 months from date of shipment, whichever occurs first. Should service be necessary, this warranty covers:

USA only: The Powerware 9315, 9330, 9335 three-phase UPS products are sold with a standard factory warranty (described below), start up, and extended labor service. All three-phase UPS installations will have an authorized Invensys Powerware Service Engineer or Agent perform startup or the factory warranty and extended labor service will be void. The included first year extended labor service provides for a complete 12 months of onsite labor for your UPS purchase.

Worldwide: All parts requiring replacement for the Factory Warranty period.

If, in the opinion of Invensys Powerware, the Unit fails to meet published specifications and the defect is within the terms of this warranty, the Unit will be repaired or replaced at the option of Invensys Powerware with no charge for replacement parts. Labor required, to make upgrades, repairs or replacement installation, is not included under the terms of this Limited Warranty, except for labor and travel costs required during the first 90 days of this warranty (USA only), provided that startup of the unit onsite, has been performed by Invensys Powerware or its agent. Equipment sold, but not manufactured by Invensys Powerware, and only the manufacturer of such equipment shall warrant this equipment and is not included as part of this warranty agreement. Equipment repaired or replaced pursuant to this warranty will be warranted for the remaining portion of the original warranty subject to all the terms thereof.

This warranty is not valid unless an authorized Invensys Powerware Service Engineer or Agent performs startup and commissioning. This warranty does not apply to any Unit that has been subject to neglect, accident, abuse, misuse, misapplication, incorrect installation, or that has been subject to repair or alteration, not authorized in writing by Invensys Powerware personnel or performed by an authorized Invensys Powerware Service Engineer or Agent. Purchaser shall be invoiced for, and shall pay for, all services not expressly provided for by the terms hereof, including, without limitation, site calls involving an inspection that determines no corrective maintenance is required.

THIS WARRANTY IS THE PURCHASER’S (USER’S) SOLE REMEDY AND IS EXPRESSLY IN LIEU OF, AND THERE ARE NOT OTHER, EXPRESSED OR IMPLIED GUARANTEES OR WARRANTIES (INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PURPOSE, WHICH ARE EXPRESSLY DISCLAIMED). In no case will Invensys Powerware’s liability under this Warranty exceed the replacement value of the Unit warranted.

Invensys Powerware’s obligation, under said warranty, is expressly conditioned upon receipt by Invensys Powerware of all payments due it (including interest charges, if any). During such time as Invensys Powerware has not received payment of any amount due it, in accordance with the Contract terms under which the equipment is sold, Invensys Powerware shall have no obligation, under said warranty; also during this time, the period of said warranty shall continue to run and the expiration of said warranty shall not be extended upon payment of the overdue amount. These limitations, to said warranty, apply even in the event that the equipment is sold initially by Invensys Powerware for resale to an ultimate end-user.

In no event shall Invensys Powerware be liable for any indirect, incidental special or consequential damages of any kind or type whatsoever, or based on any claim or cause of action, however denominated. Invensys Powerware shall not be responsible for failure to provide service or parts due to causes beyond Invensys Powerware’s reasonable control. This limited warranty applies only to the original end user of the unit.

This factory warranty will not be in effect if the End-User does not properly store the equipment, including the “trickle charge” of batteries no later than the date indicated on the packaging, before installation and does not cover shipping damages if FOB Factory. Cost for replacement equipment, installation, material freight charges travel expenses and labor of Invensys Powerware representatives will be borne by the Purchaser (user). Any advice furnished the Purchaser before or after delivery in regard to use or application of Powerware equipment is furnished without charge and on the basis that it represents Invensys Powerware’s best judgment under the circumstances. The use of any such advice by the Purchaser is solely and entirely at its own risk. Any other agreements, such as Service contracts or Sales Concessions are not means to annul this Factory Warranty.

For comment or questions, about this Limited Factory Warranty, write to the Customer Quality Representative, 3301 Spring Forest Road, Raleigh, NC 27601, or call (919) 872---3020

Powerware 9335 (80 kVA-120 kVA) Installation and Operation

W-1

164201396 REV. A 071103

 

Image 99
Contents Uninterruptible Power Supply 80 kVA 120 kVA Page Important Safety Instructions Table of Contents Operational Controls and Features Using the Control PanelUnderstanding UPS Operation Responding to System Events Product SpecificationsAppendix a Customer Information Warranty UPS Operating InstructionsMain Elements of the UPS System List of FiguresList of Tables Introduction Basic System Configurations Conventions Used in This Manual Getting Help Safety ConsiderationsSection Installation This page left intentionally blank Installing the UPS Creating an Installation PlanGetting Started Preparing for Wiring the UPS System Preparing Your SiteEnvironmental Considerations Inspecting and Unpacking Each Cabinet Powerware 9335 80 kVA and 120 kVA UPS PackagingDo not tilt cabinets more than ±10 degrees from vertical Preliminary Installation Information Installing the UPS SystemUPS Cabinet Installation Installing External Battery Power Wiring Installing Customer Connections Battery Cabinet Installation Completing the Installation ChecklistInitial Startup Installation Checklist Important Safety Instructions Installing and Connecting BatteriesThis page left intentionally blank Installing a Remote EPO Control Installation ProceduresTo Install a Remote EPO To Operate a Remote EPO Remote EPO Wire TerminationsSection Operation This page left intentionally blank Looking Inside the UPS System Understanding UPS OperationREV a Normal, Battery and Bypass Modes Normal Mode Normal ModePage Static Bypass Bypass ModePage Battery Mode Battery ModePage Maintenance Bypass Mode Maintenance Bypass ModeBoost Converter Batteries and Battery ChargerFunctional Description Input RectifierStatic Bypass Maintenance BypassGeneral Operational Controls and FeaturesUPS Operational Controls Control PanelSystem and Load ON/OFF UPS Standard Features Communications Options and AccessoriesRemote Emergency Power OFF Battery CabinetsSafety Considerations Protective Grounding Terminal Symbols, Controls, and IndicatorsDescription Using the Control PanelUsing the Control Panel Power Management DisplayLED Indicators 4 ON/OFF Startup and Shutdown Pushbuttons Pushbutton FunctionsStatus Screens Description of the LCD ScreenLoad OFF LCD Display Structure and NavigationMain Menu Screen Event Log ScreenMeasurements Screen Commands Screen Set-Up User UPS DataSET-UP Service Password Set-Up ServiceOn Line Mode Inverter Mode OFF Line Mode Bypass or Economy ModePerating Modes Line INV Maintenance Bypass ModeParallel Isolator IA2 Start-Up Procedure for the UPS UPS Operating InstructionsOperation LED Indicator Color Complete Shutdown Procedure for the UPS Line OFF Bypass Inverter Battery Load Transfer to Maintenance BypassRed This page left intentionally blank Alarms Menu, Commands, Event Log, and MeasurementsResponding to System Events Alarm Condition Meaning Suggested Solution Fault Identification and CorrectionSlot Communication Modules Communications10Single-Port Serial Card X-Slot Location on Front of Powerware 9335 UPS CabinetCommunication Port on the Single Port Serial Card 10-4 Generator on Facility Options11-2 Important Safety Instructions Maintaining the UPS SystemGeneral Perform the following checks Daily Performing Preventive MaintenanceProduct Specifications System InformationUPS System Input UPS System Output Environmental SpecificationsAppendix a Customer Information Powerware 9335 80 kVA Powerware 9335 120 kVA AC Input to Phase a #6-250 kcmils Cooper 42.4 375 Table F. Maximum Output Circuit Breaker Ratings Amperes Table E. Maximum Input Circuit Breaker Ratings AmperesTerminal Name Description Table G. Customer Interface Inputs and OutputsAlarm MNS REV a 07/11/2003 Table K. System Clearances Table J. Equipment WeightAmbient Temperature Range Powerware 9335 80kVA and 120 kVAElements Figure A-2. Powerware 9335 80 kVA and 120 kVA Label 1A, 1B, 1C, 1N 2A, 2B, 2C, 2N3A, 3B, 3C, 3N Electrical Diagram 120 kVA S06-0001ULA Powerware NW4007 Figure A-7. UPS Cabinet Dimensions Rear View 750 mm .6 inches 700 mm .6 inches 1800 mm Page Page Page Page Limited Factory Warranty for THREE-PHASE Powerware Products This page left intentionally blank

9335 specifications

The Powerware 9335 is a robust and efficient uninterruptible power supply (UPS) designed to deliver reliable power protection for critical applications. Expanding upon Eaton's tradition of offering advanced power management solutions, the Powerware 9335 is tailored for environments that demand high availability and uptime.

One of the standout features of the Powerware 9335 is its double-conversion online topology, which ensures a continuous supply of clean and regulated power. This design operates without any transfer time to battery power, effectively protecting sensitive equipment from all types of power disturbances, including surges, sags, and outages.

The UPS is available in a range of power ratings, from 8 kVA to 40 kVA, making it versatile enough to support a variety of applications ranging from small server rooms to larger data centers. The modular architecture of the Powerware 9335 allows for seamless scalability, enabling users to add additional capacity or redundancy as their power needs evolve. This feature is particularly beneficial in dynamic environments where equipment and loads can frequently change.

Another significant characteristic of the Powerware 9335 is its high efficiency, often exceeding 94% in normal operation. This efficiency not only reduces energy costs but also minimizes heat generation, leading to lower cooling requirements. The UPS employs advanced technologies such as Intelligent Power Management and Smart APM (Adaptive Power Management) to optimize power usage, further enhancing its overall performance and reducing the total cost of ownership.

The user-friendly LCD display furnishes real-time data regarding UPS status, battery condition, and power settings, facilitating proactive management and monitoring. In addition, the unit can be monitored and managed remotely, ensuring that administrators can access critical information even when they are not on-site.

The Powerware 9335 also comes equipped with various connectivity options, including USB, serial, and SNMP for seamless integration into existing IT infrastructure. Additionally, advanced communication capabilities allow for integration with building management systems, ensuring comprehensive power management and reporting.

Safety is paramount, and the Powerware 9335 incorporates numerous features designed to protect both the UPS and connected equipment. This includes overload protection, battery health monitoring, and environmental monitoring, which collectively contribute to a resilient power protection strategy.

In summary, the Powerware 9335 is an exceptional UPS offering from Eaton, featuring high availability, scalability, efficiency, and robust management options. With its advanced technologies and features, it stands out as a premier choice for organizations seeking to safeguard their critical systems and data.