5-7 Nodes and Associated Hard Drives

The SCF418 chassis contains eight individual motherboards in separate 1U nodes. Each node controls the hard drives contained within that node. Note that if a node is pulled out of the chassis, the hard drives associated with that node will power down as well. Refer to the charts below and on the following pages for your specific chassis configuration

Node

Node

4

 

Node

3

 

2

 

Node

 

 

 

1

 

 

 

 

Node:

8

 

Node:

7

Node

6

 

Node

5

 

 

 

 

 

 

Figure 5-7: Hard Drives and the Corresponding Motherboards

SCF418BC-R1K62BP

Node 4

Node 8

Controls six 2.5" HDDs, D1-D6

Controls six 2.5" HDDs, H1-H6

Node 3

Node 7

Controls six 2.5" HDDs, C1-C6

Controls six 2.5" HDDs, G1-G6

Node 2

Node 6

Controls six 2.5" HDDs, B1-B6

Controls six 2.5" HDDs, F1-F6

Node 1

Node 5

Controls six 2.5" HDDs, A1-A6

Controls six 2.5" HDDs, E1-E6

5-6

Image 43
Contents Super SCF418 Chassis Manual About This Manual PrefaceIntroduction Manual OrganizationPreface Table of Contents Chassis Setup and Maintenance Rack Installation Part Numbers Chapter IntroductionOverview Shipping ListEurope Contacting SupermicroReturning Merchandise for Service About Standardized Warning Statements Chapter Standardized Warning Statements for AC Systemsהרהזא תורהצה ןונקת Bewaar Deze Instructies 設置手順書 システムを電源に接続する前に、設置手順書をお読み下さい。 Installation InstructionsCircuit Breaker 電源切断の警告 Power Disconnection Warningםיביכר תרסה וא תנקתה ךרוצל זראמה לש ימינפה קלחל השיג ינפל 機器の設置 Equipment Installationアクセス制限区域 このユニットは、アクセス制限区域に設置されることを想定しています。 Restricted Area電池の取り扱い Battery HandlingPage הדיחיה תא Redundant Power Suppliesバックプレーンの電圧 Backplane Voltage地方および国の電気規格に準拠 機器の取り付けはその地方および国の電気規格に準拠する必要があります。 Comply with Local and National Electrical Codes製品の廃棄 Product Disposalファン・ホットスワップの警告 Hot Swap Fan Warning當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 電源コードとACアダプター Power Cable and AC AdapterPage Page Components Chapter Chassis ComponentsWhere to get Replacement Components Chassis Control Panel Chapter System InterfaceControl Panel LEDs Control Panel ButtonsSAS/SATA Drives Drive Carrier LEDsSCF418 Chassis Manual Removing Power Cords Chapter Chassis Setup and MaintenanceRemoving the Power Cord Node Node LocationsNode Removing the Node Cover Removing Nodes from the ChassisRemoving the Cover from the Node Removing a NodeOverview of the Node Node ConfigurationsSCF418BC-R1K62BP Node Layout SCF418IL-R1K62BP Node Layout SCF418IF-R1K62BP Node LayoutHard Drives and the Corresponding Motherboards Nodes and Associated Hard DrivesControls two fixed 3.5 HDDs E1-E2 Installing and Removing 2.5 Hard Drives Installing and Removing Hard DrivesRemoving 2.5 Hard Drive Carriers from the Node 2.5 Hard Drive Carrier Installing a 2.5 Drive into the Hard Drive Carrier11 Installing a 2.5 Hard Drive in the Drive Carrier Removing 3.5 Fixed Hard Drives from the Node Installing and Removing 3.5 Fixed Hard Drives14 Installing a 3.5 Fixed Hard Drive in the Node Removing the Backplane Removing and Installing the BackplaneRemoving the Backplane from the Chassis Lift the backplane up and out of the node Installing the Backplane into the Chassis Installing the BackplaneCompatible Motherboards Permanent and Optional Standoffs Installing the MotherboardInstalling the Motherboard SCF418 Pcie Slot Configurations Installing Expansion Cards19 I/O Shield Configuration Installing Rear Low-profile Expansion CardsAssembling the Pcie Slot Bracket Assembly Assembling the Pcie Slot Bracket AssemblyInstalling the Pcie Slot Bracket Assembly Installing the Pcie Slot Bracket Assembly Into the NodeInstalling the Micro LP Card Assembly Installing Rear Micro LP CardsInstalling Front Low-profile Expansion Cards 24 Assembling the Pcie Slot Bracket and Riser Card Bracket Mounting Screws Installing an Air Shroud Installing Air ShroudsAir Shrouds Removing Internal System Fans Removing and Installing System FansRemoving and Installing Internal System Fans Installing Internal System FansInstalling a Rear Exhaust Fan Removing and Installing External System FansRemoving a Rear Exhaust Fan Power Supply Replacement Replacing the Power SuppliesChanging the Power Supply SCF418 Chassis Manual Unpacking the System Chapter Rack InstallationPreparing for Setup Choosing a Setup LocationGeneral Server Precautions Rack PrecautionsRack Mounting Considerations Ambient Operating TemperatureRack Mounting Instructions Adjusting the RailsIdentifying the Sections of the Rack Rails Installing the Rails Installing the Rails on a RackInstalling the Chassis into a Rack Chassis InstallationAppendix a SCF418 Power Supply Specifications SCF418 Chassis Manual ESD Safety Guidelines Appendix B BPN-SAS-F418-B6 Backplane SpecificationsGeneral Safety Guidelines Introduction to the BPN-SAS-F418-B6 Backplane An Important Note to UsersFigure B-1 Front Connectors Front ConnectorsBackplane Main Power Connectors Front Connector and Pin DefinitionsD24 Rear Connectors and LED IndicatorsSCF418 Chassis Manual Appendix C BPN-SAS-F418B2R Backplane Specifications Introduction to the BPN-SAS-F418-B2R Backplane BPN-SAS-F418-B2R Backplane Main Power Connector BAR Code