Chapter 5: Chassis Setup and Maintenance
5-14 Replacing the Power Supplies
The SCF418 chassis includes redundant 1620W power supplies. These power sup- plies are
Power Supply Replacement
The SCF418 chassis utilizes redundant power supplies. In the unlikely event that the power supply unit needs to be replaced, one power supply can be removed, without powering down the system. Replacement units can be ordered directly from Supermicro (See the contact information in the Preface of this manual).
Changing the Power Supply
1.Disconnect the AC power cord on the back of the failed power supply.
2.Press the release tab on the back of the power supply and pull the power supply out using the handle provided.
3.Push the replacement power supply module into the power bay until it clicks into the locked position.
4.Plug the AC power cord back into the module and power up the node.
Release Tab