X9SPU-F Motherboard User’s Manual
Log System Boot Event
This option toggles the System Boot Event logging to enabled or disabled. The options are Disabled and Enabled.
MECI
The Multiple Event Count Increment (MECI) counter counts the number of times a duplicate event must happen before the MECI counter is incremented. This is a numeric value. The default value is 1.
METW
The Multiple Event Time Window (METW) defines number of minutes must pass between duplicate log events before MECI is incremented. This is in minutes, from 0 to 99. The default value is 60.
Log OEM Codes
Use this item to enable the logging of EFI Status Codes as OEM Codes. The op- tions are Disabled and Enabled.
Convert OEM Codes
Set this item to enabled to convert EFI Status Codes to standard Smbios Types. The options are Disabled and Enabled.
View SmBIOS Event Log
This feature displays the contents of the SmBIOS Event Log.