Chapter 4: AMI BIOS
use 3F8 as its I/O port address and IRQ 4 for the interrupt address. The options for Serial Port1 are Disabled, 3F8/IRQ4, 2E8/IRQ3. The options for Serial Port2 are Disabled, 2F8/IRQ3, and 2E8/IRQ3.
Onboard Floppy Controller
Select Enabled to enable the onboard Floppy Controller. The options are Enabled and Disabled.
Remote Access Configuration
Remote Access
This allows the user to enable the Remote Access feature. The options are Dis- abled and Enabled.
If Remote Access is set to Enabled, the following items will display:
Serial Port Number
This feature allows the user to decide which serial port to be used for Console Redirection. The options are COM 1, COM 2 and COM 3.
Note: Serial Over LAN (SOL) is enabled on COM 3 on the
Serial Port Mode
This feature allows the user to set the serial port mode for Console Redirection. The options are 115200 8, n 1; 57600 8, n, 1; 38400 8, n, 1; 19200 8, n, 1; and 9600 8, n, 1.
Flow Control
This feature allows the user to set the flow control for Console Redirection. The options are None, Hardware, and Software.
Redirection After BIOS POST
Select Disabled to turn off Console Redirection after
Terminal Type
This feature allows the user to select the target terminal type for Console Redi- rection. The options are ANSI, VT100, and