Seagate 100620418 Reliability and service, Seek errors, Interface errors, Preventive maintenance

Page 24

6.1.3Seek errors

A seek error is defined as a failure of the drive to position the heads to the addressed track. After detecting an initial seek error, the drive automatically performs an error recovery process. If the error recovery process fails, a seek positioning error (Error code = 15h or 02h) will be reported with a Hardware error (04h) in the Sense Key. Recoverable seek errors are specified at Less than 10 errors in 108 seeks. Unrecoverable seek errors (Sense Key = 04h) are classified as drive failures.

6.1.4Interface errors

An interface error is defined as a failure of the receiver on a port to recover the data as transmitted by the device port connected to the receiver. The error may be detected as a running disparity error, illegal code, loss of word sync, or CRC error.

6.2Reliability and service

You can enhance the reliability of Constellation.2 disk drives by ensuring that the drive receives adequate cool- ing. Section 7.0 provides temperature measurements and other information that may be used to enhance the service life of the drive. Section 11.2 provides recommended air-flow information.

6.2.1Annualized Failure Rate (AFR) and Mean Time Between Failure (MTBF)

The production disk drive shall achieve an AFR of 0.62% (MTBF of 1,400,000 hours) when operated in an environment that ensures the HDA case temperatures do not exceed the values specified in Section 7.5. Oper- ation at case temperatures outside the specifications in Section 7.5 may increase the product AFR (decrease the MTBF). The AFR (MTBF) is a population statistic not relevant to individual units.

The AFR (MTBF) specification is based on the following assumptions for Enterprise Storage System environ- ments:

8760 power-on hours per year.

250 average on/off cycles per year.

Operations at nominal voltages.

Systems will provide adequate cooling to ensure the case temperatures specified in Section 7.5 are not exceeded. Temperatures outside the specifications in Section 7.5 will increase the product AFR and decrease the MTBF.

6.2.2Preventive maintenance

No routine scheduled preventive maintenance is required.

6.2.3Hot plugging the drive

When a disk is powered on by switching the power or hot plugged, the drive runs a self test before attempting to communicate on its’ interfaces. When the self test completes successfully, the drive initiates a Link Reset starting with OOB. An attached device should respond to the link reset. If the link reset attempt fails, or any time the drive looses sync, the drive initiated link reset. The drive will initiate link reset once per second but alternates between port A and B. Therefore each port will attempt a link reset once per 2 seconds assuming both ports are out of sync.

If the self-test fails, the drive does not respond to link reset on the failing port.

Note. It is the responsibility of the systems integrator to assure that no temperature, energy, voltage haz- ard, or ESD potential hazard is presented during the hot connect/disconnect operation. Discharge the static electricity from the drive carrier prior to inserting it into the system.

16

Constellation.2 SAS Product Manual, Rev. H

Image 24
Contents ST91000640SSST91000641SS ST9500620SSST9500621SS ST91000642SS ST9500622SSStandard Models Self-Encrypting Drive Models SED Fips 140-2 ModelsRevision history Contents Defect and error management InstallationAbout Fips About self-encrypting drives Interface requirementsPage Constellation.2 SAS Product Manual, Rev. H List of Figures Constellation.2 SAS Product Manual, Rev. H Seagate Technology support services Seagate Online Support and ServicesScope Applicable standards and reference documentation StandardsElectromagnetic compatibility Electromagnetic susceptibilityElectromagnetic compliance Electromagnetic compliance for the European UnionAustralian C-Tick Korean KCCEuropean Union Restriction of Hazardous Substances RoHS China Restriction of Hazardous Substances RoHS DirectiveReference documents Self-Encrypting Drives Reference ManualGeneral description Standard features Media descriptionPerformance ReliabilityFormatted capacities Programmable drive capacityFactory-installed options Performance characteristics Internal drive characteristicsSeek performance characteristics Access timeGeneral performance characteristics Start/stop timePrefetch/multi-segmented cache control Cache operationCaching write data Prefetch operationReliability specifications Error ratesRecoverable Errors Unrecoverable ErrorsReliability and service Seek errorsInterface errors Preventive maintenance4 S.M.A.R.T Controlling S.M.A.R.TPerformance impact Reporting controlTemperature Log Page 0Dh Parameter Code Description Predictive failuresThermal monitor State of the drive prior to testing Drive Self Test DSTDST failure definition ImplementationShort and extended tests Short test Function Code 001bExtended test Function Code 010b Log page entriesProduct warranty ShippingStorage Product repair and return informationPhysical/electrical specifications PowerChoiceTM power managementPowerChoice modes AC power requirements DC power requirements1000GB drive Standard & SED model DC power requirements 500GB drive Standard & SED model DC power requirements General DC power requirement notes Power sequencingConducted noise immunity Current profiles TB model current profilesGB model current profiles Power dissipation 1TB model drive in 3Gb operation1TB model drive in 6Gb operation 500GB model drive in 3Gb operation 500GB model drive in 6Gb operation Temperature a. Operating Environmental limitsRelative humidity Effective altitude sea level a. Operating Shock and vibrationShock Recommended mounting Air cleanliness Vibration a. Operating-normalAcoustics Corrosive environmentSee Section Constellation.2 SAS Product Manual, Rev. H Mechanical specifications Mounting configuration dimensionsAbout Fips PurposeValidation Program Seagate Enterprise SEDExample of Fips tamper evidence labels Controlled access Admin SPAbout self-encrypting drives Data encryptionAuthenticated firmware download Random number generator RNGDrive locking Data bandsPower requirements Supported commandsDefect and error management Drive internal defects/errorsDrive error recovery procedures SAS system errors Background Media Scan Media Pre-ScanDeferred Auto-Reallocation Setting and determining the current Type Level Idle Read After WriteProtection Information PI Levels of PIIdentifying a Protection Information drive Installation Drive orientationCooling Air flowDrive mounting GroundingSAS features Interface requirementsDual port support Scsi commands supported Supported commandsSupported commands Supported commands Supported commands Mode Sense data Inquiry dataConstellation.2 inquiry data Page Block Descriptor 00 00 00 00 3a 38 60 30 00 00 00 00 00 00 02 Miscellaneous operating features and conditions Miscellaneous featuresMiscellaneous status SAS physical interface Datum B Section C C Section a a Physical characteristics Connector requirementsElectrical description Pin descriptionsSignal characteristics PowerSAS transmitters and receivers Ready LED OutSAS-2 Specification Compliance LED drive signalDifferential signals General interface characteristicsIndex NumericsKCC Msid Mtbf See also cooling Page Constellation.2 SAS Product Manual, Rev. H Page Seagate Technology LLC Americas