6.2.6.2.3Short and extended tests

DST has two testing options:

1.short

2.extended

These testing options are described in the following two subsections.

Each test consists of three segments: an electrical test segment, a servo test segment, and a read/verify scan segment.

Short test (Function Code: 001b)

The purpose of the short test is to provide a time-limited test that tests as much of the drive as possible within 120 seconds. The short test does not scan the entire media surface, but does some fundamental tests and scans portions of the media. A complete read/verify scan is not performed and only factual failures will report a fault condition. This option provides a quick confidence test of the drive.

Extended test (Function Code: 010b)

The objective of the extended test option is to empirically test critical drive components. For example, the seek tests and on-track operations test the positioning mechanism. The read operation tests the read head element and the media surface. The write element is tested through read/write/read operations. The integrity of the media is checked through a read/verify scan of the media. Motor functionality is tested by default as a part of these tests.

The anticipated length of the Extended test is reported through the Control Mode page.

6.2.6.2.4Log page entries

When the drive begins DST, it creates a new entry in the Self-test Results Log page. The new entry is created by inserting a new self-test parameter block at the beginning of the self-test results log parameter section of the log page. Existing data will be moved to make room for the new parameter block. The drive reports 20 param- eter blocks in the log page. If there are more than 20 parameter blocks, the least recent parameter block will be deleted. The new parameter block will be initialized as follows:

1.The Function Code field is set to the same value as sent in the DST command

2.The Self-Test Results Value field is set to Fh

3.The drive will store the log page to non-volatile memory

After a self-test is complete or has been aborted, the drive updates the Self-Test Results Value field in its Self- Test Results Log page in non-volatile memory. The host may use Log Sense to read the results from up to the last 20 self-tests performed by the drive. The self-test results value is a 4-bit field that reports the results of the test. If the field is set to zero, the drive passed with no errors detected by the DST. If the field is not set to zero, the test failed for the reason reported in the field.

The drive will report the failure condition and LBA (if applicable) in the Self-test Results Log parameter. The Sense key, ASC, ASCQ, and FRU are used to report the failure condition.

6.2.6.2.5Abort

There are several ways to abort a diagnostic. You can use a SCSI Bus Reset or a Bus Device Reset message to abort the diagnostic.

You can abort a DST executing in background mode by using the abort code in the DST Function Code field. This will cause a 01 (self-test aborted by the application client) code to appear in the self-test results values log. All other abort mechanisms will be reported as a 02 (self-test routine was interrupted by a reset condition).

20

Constellation.2 SAS Product Manual, Rev. H

Image 28
Contents ST91000640SSST91000641SS ST9500620SSST9500621SS ST91000642SS ST9500622SSStandard Models Self-Encrypting Drive Models SED Fips 140-2 ModelsRevision history Contents Defect and error management InstallationAbout Fips About self-encrypting drives Interface requirementsPage Constellation.2 SAS Product Manual, Rev. H List of Figures Constellation.2 SAS Product Manual, Rev. H Seagate Technology support services Seagate Online Support and ServicesScope Applicable standards and reference documentation StandardsElectromagnetic compatibility Electromagnetic susceptibilityElectromagnetic compliance Electromagnetic compliance for the European UnionAustralian C-Tick Korean KCCEuropean Union Restriction of Hazardous Substances RoHS China Restriction of Hazardous Substances RoHS DirectiveReference documents Self-Encrypting Drives Reference ManualGeneral description Standard features Media descriptionPerformance ReliabilityFormatted capacities Programmable drive capacityFactory-installed options Performance characteristics Internal drive characteristicsSeek performance characteristics Access timeGeneral performance characteristics Start/stop timePrefetch/multi-segmented cache control Cache operationCaching write data Prefetch operationReliability specifications Error ratesRecoverable Errors Unrecoverable ErrorsReliability and service Seek errorsInterface errors Preventive maintenance4 S.M.A.R.T Controlling S.M.A.R.TPerformance impact Reporting controlPredictive failures Temperature Log Page 0Dh Parameter Code DescriptionThermal monitor State of the drive prior to testing Drive Self Test DSTDST failure definition ImplementationShort and extended tests Short test Function Code 001bExtended test Function Code 010b Log page entriesProduct warranty ShippingStorage Product repair and return informationPowerChoiceTM power management Physical/electrical specificationsPowerChoice modes AC power requirements DC power requirements1000GB drive Standard & SED model DC power requirements 500GB drive Standard & SED model DC power requirements Power sequencing General DC power requirement notesConducted noise immunity Current profiles TB model current profilesGB model current profiles Power dissipation 1TB model drive in 3Gb operation1TB model drive in 6Gb operation 500GB model drive in 3Gb operation 500GB model drive in 6Gb operation Environmental limits Temperature a. OperatingRelative humidity Shock and vibration Effective altitude sea level a. OperatingShock Recommended mounting Air cleanliness Vibration a. Operating-normalAcoustics Corrosive environmentSee Section Constellation.2 SAS Product Manual, Rev. H Mechanical specifications Mounting configuration dimensionsAbout Fips PurposeValidation Program Seagate Enterprise SEDExample of Fips tamper evidence labels Controlled access Admin SPAbout self-encrypting drives Data encryptionAuthenticated firmware download Random number generator RNGDrive locking Data bandsPower requirements Supported commandsDrive internal defects/errors Defect and error managementDrive error recovery procedures SAS system errors Media Pre-Scan Background Media ScanDeferred Auto-Reallocation Setting and determining the current Type Level Idle Read After WriteProtection Information PI Levels of PIIdentifying a Protection Information drive Installation Drive orientationCooling Air flowDrive mounting GroundingSAS features Interface requirementsDual port support Scsi commands supported Supported commandsSupported commands Supported commands Supported commands Inquiry data Mode Sense dataConstellation.2 inquiry data Page Block Descriptor 00 00 00 00 3a 38 60 30 00 00 00 00 00 00 02 Miscellaneous features Miscellaneous operating features and conditionsMiscellaneous status SAS physical interface Datum B Section C C Section a a Physical characteristics Connector requirementsElectrical description Pin descriptionsSignal characteristics PowerSAS transmitters and receivers Ready LED OutSAS-2 Specification Compliance LED drive signalDifferential signals General interface characteristicsIndex NumericsKCC Msid Mtbf See also cooling Page Constellation.2 SAS Product Manual, Rev. H Page Seagate Technology LLC Americas