Medalist Pro 2160N, Rev. B | 15 |
Additional drive options
13 11 9 7 5 3 1
14 12 10 8 6 4 2
Parity Enabled
Parity Disabled
Motor Start Enabled
Motor Start Disabled
Remote LED connection
Figure 7. Options jumper settings
The options jumper block allows you to configure your drive for several additional configuration options. The drawing in Figure 7 shows how to place jumpers to enable each optional feature. A brief description of each option is included.
Parity Enable. Parity is enabled when a jumper is installed on pins 7 and 8 (default). To disable parity, remove this jumper.
Motor Start Enable. The Motor Start option causes the drive to wait for a Start/Stop Unit command from the host before starting or stopping the spindle motor. Motor start is enabled when a jumper is installed on pins 11 and 12.