can be used to set this trip point. The default value for this drive is 68°C, however, you can set it to any value in the range of 0 to 68°C. If you specify a temperature greater than 68°C in this field, the temperature is rounded down to 68°C. A sense code is sent to the host to indicate the rounding of the parameter field.
Table 11: Temperature Log Page (0Dh)
Parameter Code | Description |
|
|
0000h | Primary Temperature |
|
|
0001h | Reference Temperature |
|
|
5.2.6Drive Self Test (DST)
Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a failed unit. DST validates the functionality of the drive at a system level.
There are two test coverage options implemented in DST:
1.Extended test
2.Short text
The most thorough option is the extended test that performs various tests on the drive and scans every logical block address (LBA) of the drive. The short test is
If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test, remove it from service and return it to Seagate for service.
5.2.6.1DST failure definition
The drive will present a “diagnostic failed” condition through the
The following conditions are considered DST failure conditions:
•Seek error after retries are exhausted
•
•Read error after retries are exhausted
•Write error after retries are exhausted
Recovered errors will not be reported as diagnostic failures.
5.2.6.2Implementation
This section provides all of the information necessary to implement the DST function on this drive.
5.2.6.2.1State of the drive prior to testing
The drive must be in a ready state before issuing the Send Diagnostic command. There are multiple reasons why a drive may not be ready, some of which are valid conditions, and not errors. For example, a drive may be in process of doing a format, or another DST. It is the responsibility of the host application to determine the “not ready” cause.
While not technically part of DST, a Not Ready condition also qualifies the drive to be returned to Seagate as a failed drive.
Cheetah 15K.6 SAS Product Manual, Rev. B | 19 |