Seagate ST3300056SS (FDE) Temperature Log Page 0Dh Parameter Code Description, Implementation

Page 23

can be used to set this trip point. The default value for this drive is 68°C, however, you can set it to any value in the range of 0 to 68°C. If you specify a temperature greater than 68°C in this field, the temperature is rounded down to 68°C. A sense code is sent to the host to indicate the rounding of the parameter field.

Table 11: Temperature Log Page (0Dh)

Parameter Code

Description

 

 

0000h

Primary Temperature

 

 

0001h

Reference Temperature

 

 

5.2.6Drive Self Test (DST)

Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a failed unit. DST validates the functionality of the drive at a system level.

There are two test coverage options implemented in DST:

1.Extended test

2.Short text

The most thorough option is the extended test that performs various tests on the drive and scans every logical block address (LBA) of the drive. The short test is time-restricted and limited in length—it does not scan the entire media surface, but does some fundamental tests and scans portions of the media.

If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test, remove it from service and return it to Seagate for service.

5.2.6.1DST failure definition

The drive will present a “diagnostic failed” condition through the self-tests results value of the diagnostic log page if a functional failure is encountered during DST. The channel and servo parameters are not modified to test the drive more stringently, and the number of retries are not reduced. All retries and recovery processes are enabled during the test. If data is recoverable, no failure condition will be reported regardless of the number of retries required to recover the data.

The following conditions are considered DST failure conditions:

Seek error after retries are exhausted

Track-follow error after retries are exhausted

Read error after retries are exhausted

Write error after retries are exhausted

Recovered errors will not be reported as diagnostic failures.

5.2.6.2Implementation

This section provides all of the information necessary to implement the DST function on this drive.

5.2.6.2.1State of the drive prior to testing

The drive must be in a ready state before issuing the Send Diagnostic command. There are multiple reasons why a drive may not be ready, some of which are valid conditions, and not errors. For example, a drive may be in process of doing a format, or another DST. It is the responsibility of the host application to determine the “not ready” cause.

While not technically part of DST, a Not Ready condition also qualifies the drive to be returned to Seagate as a failed drive.

Cheetah 15K.6 SAS Product Manual, Rev. B

19

Image 23
Contents ST3146356SS ST3450856SSST3300656SS Page Contents Interface requirements Defect and error managementInstallation Seagate Technology support servicesModel Number Full Disk Encryption FDE ScopeCheetah 15K.6 SAS Product Manual, Rev. B Electromagnetic susceptibility Standards, compliance and reference documentsStandards Electromagnetic compatibilityEuropean Union Restriction of Hazardous Substances RoHS ComplianceReference documents Cheetah 15K.6 SAS Product Manual, Rev. B General description Performance Standard featuresMedia description Programmable drive capacity Factory-installed optionsReliability Formatted capacitiesCheetah 15K.6 SAS Product Manual, Rev. B Seek time Performance characteristicsInternal drive characteristics Access time176 144 100 Format command execution time minutesGeneral performance characteristics Start/stop timeCache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataUnrecoverable Errors Reliability specificationsError rates Recoverable Errors Preventive maintenance Reliability and service Seek errors Interface errorsMilliseconds 4 S.M.A.R.TControlling S.M.A.R.T Performance impactThermal monitor Reporting controlDetermining rate Predictive failuresDST failure definition Temperature Log Page 0Dh Parameter Code DescriptionState of the drive prior to testing Drive Self Test DSTExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bProduct repair and return information Product warrantyAbort ShippingCheetah 15K.6 SAS Product Manual, Rev. B ST3450856SS DC power requirements Physical/electrical specificationsAC power requirements DC power requirementsST3300656SS Gbit mode Amps ST3450056SS FDE DC power requirementsST3300656SS DC power requirements ST3450056SS FDE Gbit mode AmpsST3146356SS Gbit mode Amps ST3300056SS FDE DC power requirementsST3146356SS DC power requirements ST3300056SS FDE Gbit mode AmpsST3146756SS FDE Gbit mode Amps ST3146756SS FDE DC power requirementsCurrent profiles Power sequencingConducted noise immunity Typical 450GB current profiles Typical 146GB current profiles ST3450856SS model Power dissipationST3450056SS FDE model ST3300656SS model ST3300056SS FDE model ST3146356SS model ST3146756SS FDE model in 3 Gbit operation Environmental limits TemperatureShock Relative humidityEffective altitude sea level Shock and vibrationRecommended mounting Package size Packaged/product weight Drop heightCorrosive environment Air cleanlinessVibration AcousticsMechanical specifications Physical dimensions Cheetah 15K.6 SAS Product Manual, Rev. B Drive error recovery procedures Defect and error managementDrive internal defects/errors 51.87 Media Pre-Scan SAS system errorsBackground Media Scan Idle Read After Write Deferred Auto-ReallocationCooling InstallationDrive orientation Air flow Grounding Drive mountingCheetah 15K.6 SAS Product Manual, Rev. B Interface requirements SAS featuresDual port support Command name Command code Supported Scsi commands supportedCommands supported by Cheetah 15K.6 SAS family drives Commands supported by Cheetah 15K.6 SAS family drives Commands supported by Cheetah 15K.6 SAS family drives Commands supported by Cheetah 15K.6 SAS family drives Bytes Data hex Inquiry dataMode Sense data Mode Pages 2.1 ST3450856SS/ST3450056SS Mode Sense data2.2 ST3300656SS/ST3300056SS Mode Sense data 2.3 ST3146356SS/ST3146756SS Mode Sense data SAS physical interface Miscellaneous operating features and conditionsMiscellaneous features Miscellaneous statusPhysical interface Datum B Connector requirements Physical characteristicsSAS pin descriptions Pin Signal name Signal typeElectrical description Pin descriptionsReady LED Out Signal characteristicsPower SAS transmitters and receiversEye masks Eye masks overview LED drive signalDifferential signals General interface characteristicsNormalized time in UI Receive eye maskJitter tolerance masks Absolute amplitudeFrequency in kHz Peak-toSinusoidal JitterSignal characteristica Units Gbps Transmitter signal characteristicsMaximum allowable jitter Receiver signal characteristicsSignal characteristic Units Gbps Impedance requirements Sheet 1 Impedance specificationsReceiver jitter tolerance Compliant jitter test pattern CjtpatElectrical TxRx connections Transmitter characteristicsImpedance requirements Sheet 2 = -5,437dB Shows the zero-length test load Receiver characteristics Cheetah 15K.6 SAS Product Manual, Rev. B Technical Support Seagate Technology support servicesInternet Presales SupportData Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Numerics IndexIraw SAS See also cooling