Seagate ST3146854LC, ST3146756SS (FDE), ST3146356SSIM manual Interface requirements, SAS features

Page 55

9.0Interface requirements

This section partially describes the interface requirements as implemented on Cheetah 15K.6 drives. Addi- tional information is provided in the SAS Interface Manual (part number 100293071).

9.1SAS features

This section lists the SAS-specific features supported by Cheetah 15K.6 drives.

9.1.1task management functions

Table 19 lists the SAS task management functions supported.

Table 19: SAS task management functions supported

Task name

Supported

 

 

Abort Task

Yes

 

 

Clear ACA

Yes

 

 

Clear task set

Yes

 

 

Abort task set

Yes

 

 

Logical Unit Reset

Yes

 

 

Query Task

Yes

 

 

9.1.2task management responses

Table 20 lists the SAS response codes returned for task management functions supported.

Table 20: Task management response codes

Function name

Response code

 

 

Function complete

00

 

 

Invalid frame

02

 

 

Function not supported

04

 

 

Function failed

05

 

 

Function succeeded

08

 

 

Invalid logical unit

09

 

 

Cheetah 15K.6 SAS Product Manual, Rev. B

51

Image 55
Contents ST3300656SS ST3450856SSST3146356SS Page Contents Interface requirements Defect and error managementInstallation Seagate Technology support servicesModel Number Full Disk Encryption FDE ScopeCheetah 15K.6 SAS Product Manual, Rev. B Electromagnetic susceptibility Standards, compliance and reference documentsStandards Electromagnetic compatibilityEuropean Union Restriction of Hazardous Substances RoHS ComplianceReference documents Cheetah 15K.6 SAS Product Manual, Rev. B General description Media description Standard featuresPerformance Programmable drive capacity Factory-installed optionsReliability Formatted capacitiesCheetah 15K.6 SAS Product Manual, Rev. B Seek time Performance characteristicsInternal drive characteristics Access time176 144 100 Format command execution time minutesGeneral performance characteristics Start/stop timeCache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataUnrecoverable Errors Reliability specificationsError rates Recoverable ErrorsPreventive maintenance Reliability and serviceSeek errors Interface errorsMilliseconds 4 S.M.A.R.TControlling S.M.A.R.T Performance impactThermal monitor Reporting controlDetermining rate Predictive failuresDST failure definition Temperature Log Page 0Dh Parameter Code DescriptionState of the drive prior to testing Drive Self Test DSTExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bProduct repair and return information Product warrantyAbort ShippingCheetah 15K.6 SAS Product Manual, Rev. B ST3450856SS DC power requirements Physical/electrical specificationsAC power requirements DC power requirementsST3300656SS Gbit mode Amps ST3450056SS FDE DC power requirementsST3300656SS DC power requirements ST3450056SS FDE Gbit mode AmpsST3146356SS Gbit mode Amps ST3300056SS FDE DC power requirementsST3146356SS DC power requirements ST3300056SS FDE Gbit mode AmpsST3146756SS FDE Gbit mode Amps ST3146756SS FDE DC power requirementsConducted noise immunity Power sequencingCurrent profiles Typical 450GB current profiles Typical 146GB current profiles ST3450856SS model Power dissipationST3450056SS FDE model ST3300656SS model ST3300056SS FDE model ST3146356SS model ST3146756SS FDE model in 3 Gbit operation Environmental limits TemperatureShock Relative humidityEffective altitude sea level Shock and vibrationRecommended mounting Package size Packaged/product weight Drop heightCorrosive environment Air cleanlinessVibration AcousticsMechanical specifications Physical dimensions Cheetah 15K.6 SAS Product Manual, Rev. B Drive internal defects/errors Defect and error managementDrive error recovery procedures 51.87 Background Media Scan SAS system errorsMedia Pre-Scan Idle Read After Write Deferred Auto-ReallocationDrive orientation InstallationCooling Air flow Grounding Drive mountingCheetah 15K.6 SAS Product Manual, Rev. B Interface requirements SAS featuresDual port support Commands supported by Cheetah 15K.6 SAS family drives Scsi commands supportedCommand name Command code Supported Commands supported by Cheetah 15K.6 SAS family drives Commands supported by Cheetah 15K.6 SAS family drives Commands supported by Cheetah 15K.6 SAS family drives Bytes Data hex Inquiry dataMode Sense data Mode Pages 2.1 ST3450856SS/ST3450056SS Mode Sense data2.2 ST3300656SS/ST3300056SS Mode Sense data 2.3 ST3146356SS/ST3146756SS Mode Sense data SAS physical interface Miscellaneous operating features and conditionsMiscellaneous features Miscellaneous statusPhysical interface Datum B Connector requirements Physical characteristicsSAS pin descriptions Pin Signal name Signal typeElectrical description Pin descriptionsReady LED Out Signal characteristicsPower SAS transmitters and receiversEye masks Eye masks overview LED drive signalDifferential signals General interface characteristicsNormalized time in UI Receive eye maskJitter tolerance masks Absolute amplitudeFrequency in kHz Peak-toSinusoidal JitterSignal characteristica Units Gbps Transmitter signal characteristicsSignal characteristic Units Gbps Receiver signal characteristicsMaximum allowable jitter Impedance requirements Sheet 1 Impedance specificationsReceiver jitter tolerance Compliant jitter test pattern CjtpatImpedance requirements Sheet 2 Transmitter characteristicsElectrical TxRx connections = -5,437dB Shows the zero-length test load Receiver characteristics Cheetah 15K.6 SAS Product Manual, Rev. B Technical Support Seagate Technology support servicesInternet Presales SupportData Recovery Services Authorized Service Centers Warranty ServiceData Recovery Services Call Center Toll-free Direct dial Numerics IndexIraw SAS See also cooling