14 | U Series CE Family Product Manual, Rev. A |
1.10 Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:
Test | Description | Performance | Reference |
|
| Level | Standard |
|
|
|
|
|
|
|
|
Electrostatic | Contact, HCP, VCP: ± 4 kV; Air: | B | EN |
discharge | ± 8 kV |
|
|
|
|
|
|
Radiated RF | 80 to 1,000 MHz, 3 V/m, | A | EN |
immunity | 80% AM with 1 kHz sine |
| ENV 50204: 95 |
| 900 MHz, 3 V/m, 50% pulse |
|
|
| modulation @ 200 Hz |
|
|
|
|
|
|
Electrical fast | ± 1 kV on AC mains, ± 0.5 kV | B | EN |
transient | on external I/O |
|
|
|
|
|
|
Surge | ± 1 kV differential, ± 2 kV com- | B | EN |
immunity | mon, AC mains |
|
|
|
|
|
|
Conducted | 150 kHz to 80 MHz, 3 Vrms, | A | EN |
RF | 80% AM with 1 kHz sine |
|
|
immunity |
|
|
|
|
|
|
|
Voltage dips, | 0% open, 5 seconds | C | EN |
interrupts | 0% short, 5 seconds | C |
|
| 40%, 0.10 seconds | C |
|
| 70%, 0.01 seconds | B |
|
|
|
|
|
1.11 Reliability
Nonrecoverable read errors | 1 per 1013 bits read, max |
Mean time between failures | 600,000 |
| 25°C ambient temperature) |
Contact | 50,000 cycles |
| (at nominal voltage and temperature, with |
| 60 cycles per hour and a 50% duty cycle) |
Preventive maintenance | None required |
1.12Agency certification 1.12.1 Safety certification
The drives are recognized in accordance with UL 1950 and CSA C22.2
(950)and meet all applicable sections of IEC950 and EN 60950 as tested by TUV North America.