20
Installing the power supply
A power supply and AC power cord are available if desired. The power supply is configured before shipment to operate in one of two AC input voltage ranges. The voltage select plate on the power supply (see Figure 8) indicates the factory- preset voltage range. You may change the voltage range by setting the voltage select switch to the desired range.
Setting the voltage range
Caution. The power supply will be damaged if the voltage select is set for the low range
1.Ensure that the AC power cable is disconnected from the power supply.
2.To change the voltage range, perform the following steps:
a.Remove the screw that secures the voltage select plate to the power supply and remove the plate from the power supply. Retain the plate and all hardware.
b.Set the voltage select switch to the desired range.
c.Reverse the voltage select plate and install the plate on the power supply to lock the switch in the desired range.
d.Replace the existing AC power cable with the AC power cable specified for the new operating voltage. Refer to section 4 for information about ordering a replacement AC power cord.
Mounting the power supply
Note. The mounting screw threads must be completely engaged in the power supply chassis but must not exceed the limits given in the next step.
1.Select mounting screws that meet the following criteria for insertion depth:
•For bottom
•For side
2.Mount the power supply in the desired location with four
3.Connect a ground strap between the chassis safety ground screw on the power supply and the cabinet ground.
4.Attach the AC power cord to the power supply connector J1. Do not connect the power cord to site power until directed.