Seagate ST3400755FC manual Parameter Code Description, Drive Self Test DST, DST failure definition

Page 29

be used to set this trip point. The default value for this drive is 68°C, however, you can set it to any value in the range of 0 to 68°C. If you specify a temperature greater than 68°C in this field, the temperature is rounded down to 68°C. A sense code is sent to the host to indicate the rounding of the parameter field.

Table 1: Temperature Log Page (0Dh)

Parameter Code

Description

 

 

0000h

Primary Temperature

 

 

0001h

Reference Temperature

 

 

5.2.6Drive Self Test (DST)

Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a failed unit. DST validates the functionality of the drive at a system level.

There are two test coverage options implemented in DST:

1.Extended test

2.Short text

The most thorough option is the extended test that performs various tests on the drive and scans every logical block address (LBA) of the drive. The short test is time-restricted and limited in length—it does not scan the entire media surface, but does some fundamental tests and scans portions of the media.

If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test, remove it from service and return it to Seagate for service.

5.2.6.1DST failure definition

The drive will present a “diagnostic failed” condition through the self-tests results value of the diagnostic log page if a functional failure is encountered during DST. The channel and servo parameters are not modified to test the drive more stringently, and the number of retries are not reduced. All retries and recovery processes are enabled during the test. If data is recoverable, no failure condition will be reported regardless of the number of retries required to recover the data.

The following conditions are considered DST failure conditions:

Seek error after retries are exhausted

Track-follow error after retries are exhausted

Read error after retries are exhausted

Write error after retries are exhausted

Recovered errors will not be reported as diagnostic failures.

5.2.6.2Implementation

This section provides all of the information necessary to implement the DST function on this drive.

5.2.6.2.1State of the drive prior to testing

The drive must be in a ready state before issuing the Send Diagnostic command. There are multiple reasons why a drive may not be ready, some of which are valid conditions, and not errors. For example, a drive may be in process of doing a format, or another DST. It is the responsibility of the host application to determine the “not ready” cause.

While not technically part of DST, a Not Ready condition also qualifies the drive to be returned to Seagate as a failed drive.

Cheetah NS FC Product Manual, Rev. B

19

Image 29
Contents ST3400755FC ST3300955FC Cheetah NS FCPage Cheetah NS FC Product Manual, Rev. B Cheetah NS FC Product Manual, Rev. B Contents Interface requirements Defect and error managementInstallation Seagate Technology support services Cheetah NS FC Product Manual, Rev. B List of Figures Page Scope Cheetah NS FC Product Manual, Rev. B Standards Standards, compliance and reference documentsElectromagnetic compatibility Electromagnetic susceptibilityCompliance Ncits TR-19 Reference documentsCheetah NS FC Product Manual, Rev. B General description Media description Standard featuresReliability PerformanceFormatted capacities Programmable drive capacityUser-installed accessories Factory-installed optionsInternal drive characteristics Performance characteristicsAccess time Seek performanceStart/stop time Format command execution time minutesGeneral performance characteristics Caching write data Prefetch/multi-segmented cache controlCache operation Prefetch operation Error rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenanceControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact MillisecondsDetermining rate Reporting controlPredictive failures Thermal monitorParameter Code Description State of the drive prior to testingDrive Self Test DST DST failure definitionShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bAbort Product warrantyShipping Product repair and return informationCheetah NS FC Product Manual, Rev. B AC power requirements Physical/electrical specificationsDC power requirements DC power requirements for ST3400755FC model Gbit AmpsDC power requirements for ST3300955FC model Gbit Amps General DC power requirement notesConducted noise immunity Power sequencingCurrent profiles Cheetah NS FC Product Manual, Rev. B ST3400755 CURRENT/POWER vs Throughput FC 4GB Power dissipationST3400755FC Random 8 Block ReadsST3300955FC ST3300955 CURRENT/POWER vs Throughput FC 4GBRelative humidity TemperatureEnvironmental limits Effective altitude sea level Package size Packaged/product weight Drop heightShock and vibration ShockRecommended mounting Vibration Air cleanlinessAcoustics Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive X表示该部件(于同类物品程度上)所含的危险和有毒物质中国RoHS MCV标准所定义的门槛值。Mounting configuration dimensions Mechanical specificationsCheetah NS FC Product Manual, Rev. B Drive error recovery procedures Defect and error managementDrive internal defects/errors 77.87 Media Pre-Scan FC-AL system errorsBackground Media Scan Idle Read After Write Deferred Auto-ReallocationDrive ID/option selection InstallationDrive orientation CoolingAir flow Drive mountingGrounding Cheetah NS FC Product Manual, Rev. B Fibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses NPort login Plogi payload Bytes Fibre Channel port loginFibre Channel Process Login Fibre Channel port login acceptNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS FC Product Manual, Rev. B Temperature page 0Dh Cheetah NS FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Sense 10 Byte Header Data Mode Data Header Miscellaneous features Miscellaneous operating features and conditionsSupported Feature or condition Miscellaneous statusPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typePin Signal name Signal type Fault LED Out PowerMotor start controls Enable port bypass signalsActive LED Out 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIHex Dec SettingArbitrated loop physical address Alpa values Device control codes Signal characteristicsTTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Internet Seagate Technology support servicesPresales Support Technical SupportData Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Numerics IndexFAN Flogi Plogi SEL ID See also cooling