Seagate ST3400755FC, ST3300955FC Active LED Out, Enable port bypass signals, Motor start controls

Page 75

9.5.8Active LED Out

The Active LED Out signal is driven by the drive as indicated in Table 22.

Table 22: Active LED Out conditions

Normal command activity

LED status

 

 

Spun down and no activity

Slow blink (20% on and 80% off a 2 sec cycle)

 

 

Spun down and activity (command executing)

On

 

 

Spun up and no activity

On

 

 

Spun up and activity (command executing)

Off

 

 

Spinning up or down

Blinks steadily (50% on and 50% off)

 

 

Format in progress, each cylinder change

Toggles on/off

 

 

The Active LED Out signal is designed to pull down the cathode of an LED. The anode is attached to the proper +5 volt supply through an appropriate current limiting resistor. The LED and the current limiting resistor are external to the drive.

9.5.9Enable port bypass signals

The – Enable Bypass Port A (– EN BYP Port A) and – Enable Bypass Port B (– EN BYP Port B) signals control the port bypass circuits (PBC) located external to the disc drive. The PBC allows a loop to remain functional in the event of a drive failure or removal. When these signals are active, low, the PBC bypasses the drive on the associated port. When an Enable Bypass signal is active, the corresponding Port Bypass LED signal in con- nector J1 is driven low by the disc drive. A pull down resistor, 1K, located with the PBC should be used to insure the bypass is enabled if the disc drive is not installed.

The Enable Bypass signal is active under failing conditions within the drive, on detection of the Loop Port Bypass primitive sequence, or on removal of the drive. In the bypass state the drive continues to receive on the inbound fibre. Enable Bypass may be deactivated by detection of a Loop Port Enable primitive sequence if the drive has completed self-test and a hardware failure is not present.

Failure modes detected by the disc drive that will enable bypass include:

Transmitter/receiver wrap test failure

Loss of receive clock

Loss of transmission clock

Drive interface hardware error

9.5.10Motor start controls

The drive’s motor is started according to the Start_1 and Start_2 signals described in Table 23. The state of these signals can be wired into the backplane socket or driven by logic on the backplane.

Table 23:

Motor start control signals

 

 

 

 

 

Case

Start_2

Start_1

Motor spin function

 

 

 

 

1

Low

Low

Motor spins up at DC power on.

 

 

 

 

2

High

Low

Motor spins up only when SCSI Start command is received.

 

 

 

 

3

Low

High

Motor spins up after a delay of 12 seconds times the modulo 8 value

 

 

 

of the numeric SEL ID of the drive from DC power on.

 

 

 

 

4

High

High

The drive will not spin up.

 

 

 

 

Cheetah NS FC Product Manual, Rev. B

65

Image 75
Contents ST3400755FC ST3300955FC Cheetah NS FCPage Cheetah NS FC Product Manual, Rev. B Cheetah NS FC Product Manual, Rev. B Contents Defect and error management InstallationInterface requirements Seagate Technology support services Cheetah NS FC Product Manual, Rev. B List of Figures Page Scope Cheetah NS FC Product Manual, Rev. B Electromagnetic susceptibility Standards, compliance and reference documentsStandards Electromagnetic compatibilityCompliance Ncits TR-19 Reference documentsCheetah NS FC Product Manual, Rev. B General description Media description Standard featuresProgrammable drive capacity PerformanceReliability Formatted capacitiesUser-installed accessories Factory-installed optionsSeek performance Performance characteristicsInternal drive characteristics Access timeFormat command execution time minutes General performance characteristicsStart/stop time Prefetch/multi-segmented cache control Cache operationCaching write data Prefetch operation Unrecoverable Errors Reliability specificationsError rates Recoverable ErrorsPreventive maintenance Reliability and serviceSeek errors Interface errorsMilliseconds 4 S.M.A.R.TControlling S.M.A.R.T Performance impactThermal monitor Reporting controlDetermining rate Predictive failuresDST failure definition State of the drive prior to testingParameter Code Description Drive Self Test DSTExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bProduct repair and return information Product warrantyAbort ShippingCheetah NS FC Product Manual, Rev. B DC power requirements for ST3400755FC model Gbit Amps Physical/electrical specificationsAC power requirements DC power requirementsDC power requirements for ST3300955FC model Gbit Amps General DC power requirement notesConducted noise immunity Power sequencingCurrent profiles Cheetah NS FC Product Manual, Rev. B Random 8 Block Reads Power dissipationST3400755 CURRENT/POWER vs Throughput FC 4GB ST3400755FCST3300955FC ST3300955 CURRENT/POWER vs Throughput FC 4GBTemperature Environmental limitsRelative humidity Shock Package size Packaged/product weight Drop heightEffective altitude sea level Shock and vibrationRecommended mounting Corrosive environment Air cleanlinessVibration AcousticsChina Restriction of Hazardous Substances RoHS Directive X表示该部件(于同类物品程度上)所含的危险和有毒物质中国RoHS MCV标准所定义的门槛值。Mounting configuration dimensions Mechanical specificationsCheetah NS FC Product Manual, Rev. B Defect and error management Drive internal defects/errorsDrive error recovery procedures 77.87 FC-AL system errors Background Media ScanMedia Pre-Scan Idle Read After Write Deferred Auto-ReallocationCooling InstallationDrive ID/option selection Drive orientationAir flow Drive mountingGrounding Cheetah NS FC Product Manual, Rev. B Interface requirements FC-AL featuresFibre Channel link service frames Link services supported Type of frameFibre Channel task management functions Fibre Channel task management responsesFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginProcess Login Plri payload Fibre Channel port login acceptFibre Channel Process Login NPort Login Accept ACC payload BytesFabric Login Flogi payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Process Login Accept ACC payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS FC Product Manual, Rev. B Temperature page 0Dh Mode Sense data Inquiry dataCheetah NS FC inquiry data Bytes Data hex Page Mode Sense 10 Byte Header Data Mode Data Header Miscellaneous status Miscellaneous operating features and conditionsMiscellaneous features Supported Feature or conditionPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Electrical descriptionPin descriptions FC-SCA pin descriptions Pin Signal name Signal type Pin Signal name Signal typeFC-AL transmitters and receivers Fault LED Out PowerEnable port bypass signals Active LED OutMotor start controls 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESISetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics TTL input characteristicsDevice control codes LED driver signals FC Differential outputFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Technical Support Seagate Technology support servicesInternet Presales SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Numerics IndexFAN Flogi Plogi SEL ID See also cooling