Seagate ST3400755FC Dual port support, Fibre Channel Arbitrated Loop options, Option Supported

Page 61

9.1.10Fibre Channel Arbitrated Loop options

Table 14 lists the FC-AL options supported by Cheetah NS FC drives.

Table 14:

FC-AL options supported

 

 

 

Option

 

Supported

 

 

OPEN Half Duplex

Accepted from another device.

 

 

OPEN Full Duplex

Sent to open another device. Accepted from another device.

 

 

Private Loop

Yes

 

 

 

Public Loop

 

Yes

 

 

Old Port State

No

 

 

Loop Position

Yes

 

 

Loop Position Report

Yes

 

 

 

9.2Dual port support

Cheetah NS FC drives have two independent FC-AL ports. These ports may be connected on independent loops or on the same loop. Port A and Port B may be connected in any order or combination.

If both ports are connected on independent loops and hard addressing is used, the drive interface address is selected through the interface connector, both ports will seek the same loop address. If no conflict, both ports will have the same loop address.

If both ports are connected in the same loop and hard addressing is used, at least one port will attempt tak- ing a soft address to prevent an address conflict.

Subject to buffer availability, the Cheetah NS FC drives support:

Concurrent port transfers—The drive supports receiving transfers on both ports at the same time when the ports are on independent loops.

Full duplex—The drive supports sending FCP_Data, FCP_RSP, FCP_XFR_RDY and ELS transfers while receiving frames on both ports.

Cheetah NS FC Product Manual, Rev. B

51

Image 61
Contents ST3400755FC ST3300955FC Cheetah NS FCPage Cheetah NS FC Product Manual, Rev. B Cheetah NS FC Product Manual, Rev. B Contents Installation Defect and error managementInterface requirements Seagate Technology support services Cheetah NS FC Product Manual, Rev. B List of Figures Page Scope Cheetah NS FC Product Manual, Rev. B Standards Standards, compliance and reference documentsElectromagnetic compatibility Electromagnetic susceptibilityCompliance Ncits TR-19 Reference documentsCheetah NS FC Product Manual, Rev. B General description Media description Standard featuresReliability PerformanceFormatted capacities Programmable drive capacityUser-installed accessories Factory-installed optionsInternal drive characteristics Performance characteristicsAccess time Seek performanceGeneral performance characteristics Format command execution time minutesStart/stop time Cache operation Prefetch/multi-segmented cache controlCaching write data Prefetch operation Error rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenanceControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact MillisecondsDetermining rate Reporting controlPredictive failures Thermal monitorParameter Code Description State of the drive prior to testingDrive Self Test DST DST failure definitionShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bAbort Product warrantyShipping Product repair and return informationCheetah NS FC Product Manual, Rev. B AC power requirements Physical/electrical specificationsDC power requirements DC power requirements for ST3400755FC model Gbit AmpsDC power requirements for ST3300955FC model Gbit Amps General DC power requirement notesConducted noise immunity Power sequencingCurrent profiles Cheetah NS FC Product Manual, Rev. B ST3400755 CURRENT/POWER vs Throughput FC 4GB Power dissipationST3400755FC Random 8 Block ReadsST3300955FC ST3300955 CURRENT/POWER vs Throughput FC 4GBEnvironmental limits TemperatureRelative humidity Effective altitude sea level Package size Packaged/product weight Drop heightShock and vibration ShockRecommended mounting Vibration Air cleanlinessAcoustics Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive X表示该部件(于同类物品程度上)所含的危险和有毒物质中国RoHS MCV标准所定义的门槛值。Mounting configuration dimensions Mechanical specificationsCheetah NS FC Product Manual, Rev. B Drive internal defects/errors Defect and error managementDrive error recovery procedures 77.87 Background Media Scan FC-AL system errorsMedia Pre-Scan Idle Read After Write Deferred Auto-ReallocationDrive ID/option selection InstallationDrive orientation CoolingAir flow Drive mountingGrounding Cheetah NS FC Product Manual, Rev. B Fibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFibre Channel task management responses Fibre Channel task management functionsFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port login Fibre Channel Process Login Fibre Channel port login accept NPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS FC Product Manual, Rev. B Temperature page 0Dh Inquiry data Mode Sense dataCheetah NS FC inquiry data Bytes Data hex Page Mode Sense 10 Byte Header Data Mode Data Header Miscellaneous features Miscellaneous operating features and conditionsSupported Feature or condition Miscellaneous statusFC-AL physical interface Physical characteristicsPhysical description Electrical description Connector requirementsPin descriptions Pin Signal name Signal type FC-SCA pin descriptions Pin Signal name Signal typeFC-AL transmitters and receivers Fault LED Out PowerActive LED Out Enable port bypass signalsMotor start controls 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIArbitrated loop physical address Alpa values SettingHex Dec TTL input characteristics Signal characteristicsDevice control codes FC Differential output LED driver signalsFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Internet Seagate Technology support servicesPresales Support Technical SupportData Recovery Services Authorized Service Centers Warranty ServiceData Recovery Services Call Center Toll-free Direct dial Numerics IndexFAN Flogi Plogi SEL ID See also cooling
Related manuals
Manual 90 pages 49.16 Kb