Seagate ST3400755FC, ST3300955FC manual Temperature page 0Dh

Page 65

Table 15: Supported commands (continued)

Command code

Supported [4]

Command name

 

 

 

 

Y

Temperature page (0Dh)

 

 

 

 

N

Application Client page (0Fh)

 

 

 

 

Y

Self Test Results page (10h)

 

 

 

 

Y

Background Medium Scan page (15h)

 

 

 

 

Y

Cache Statistics Counter page (37h)

 

 

 

 

Y

Factory Log page (3Eh)

 

 

 

4E-4Fh

N

Not used

 

 

 

50h

N

XD write

 

 

 

51h

N

XP write

 

 

 

52h

N

XD read

 

 

 

53-54h

N

Not used

 

 

 

55h

Y

Mode Select (10) [3]

 

 

 

56h

Y

Reserved (10)

 

 

 

 

Y

3rd party reserve

 

 

 

 

N

Extent reservation

 

 

 

57h

Y

Released (10)

 

 

 

58-59h

N

Not used

 

 

 

5Ah

Y

Mode Sense (10) [3]

 

 

 

5B-5Dh

N

Not used

 

 

 

5E

A

Persistent reserve in

 

 

 

5F

A

Persistent reserve out

 

 

 

60-7Fh

N

Not used

 

 

 

80h

N

XD write extended

 

 

 

81h

N

Rebuild

 

 

 

82h

N

Regenerate

 

 

 

83-8Fh

N

Not used

 

 

 

A0h

Y

Report LUNS

 

 

 

C0-DFh

N

Not used

 

 

 

EO-FFh

N

Not used

 

 

 

[1]Cheetah NS FC drives can format to 512, 520, 524 or 528 bytes per logical block.

[2]Warning. Power loss during flash programming can result in firmware corruption. This usually makes the drive inoperable.

[3]Reference Mode Sense command 1Ah for mode pages supported.

[4]Y = Yes. Command is supported.

N = No. Command is not supported.

A = Support is available on special request.

Cheetah NS FC Product Manual, Rev. B

55

Image 65
Contents ST3400755FC ST3300955FC Cheetah NS FCPage Cheetah NS FC Product Manual, Rev. B Cheetah NS FC Product Manual, Rev. B Contents Interface requirements Defect and error managementInstallation Seagate Technology support services Cheetah NS FC Product Manual, Rev. B List of Figures Page Scope Cheetah NS FC Product Manual, Rev. B Standards Standards, compliance and reference documentsElectromagnetic compatibility Electromagnetic susceptibilityCompliance Ncits TR-19 Reference documentsCheetah NS FC Product Manual, Rev. B General description Media description Standard featuresReliability PerformanceFormatted capacities Programmable drive capacityUser-installed accessories Factory-installed optionsInternal drive characteristics Performance characteristicsAccess time Seek performanceStart/stop time Format command execution time minutesGeneral performance characteristics Caching write data Prefetch/multi-segmented cache controlCache operation Prefetch operation Error rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenanceControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact MillisecondsDetermining rate Reporting controlPredictive failures Thermal monitorParameter Code Description State of the drive prior to testingDrive Self Test DST DST failure definitionShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bAbort Product warrantyShipping Product repair and return informationCheetah NS FC Product Manual, Rev. B AC power requirements Physical/electrical specificationsDC power requirements DC power requirements for ST3400755FC model Gbit AmpsDC power requirements for ST3300955FC model Gbit Amps General DC power requirement notesConducted noise immunity Power sequencingCurrent profiles Cheetah NS FC Product Manual, Rev. B ST3400755 CURRENT/POWER vs Throughput FC 4GB Power dissipationST3400755FC Random 8 Block ReadsST3300955FC ST3300955 CURRENT/POWER vs Throughput FC 4GBRelative humidity TemperatureEnvironmental limits Effective altitude sea level Package size Packaged/product weight Drop heightShock and vibration ShockRecommended mounting Vibration Air cleanlinessAcoustics Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive X表示该部件(于同类物品程度上)所含的危险和有毒物质中国RoHS MCV标准所定义的门槛值。Mounting configuration dimensions Mechanical specificationsCheetah NS FC Product Manual, Rev. B Drive error recovery procedures Defect and error managementDrive internal defects/errors 77.87 Media Pre-Scan FC-AL system errorsBackground Media Scan Idle Read After Write Deferred Auto-ReallocationDrive ID/option selection InstallationDrive orientation CoolingAir flow Drive mountingGrounding Cheetah NS FC Product Manual, Rev. B Fibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses NPort login Plogi payload Bytes Fibre Channel port loginFibre Channel Process Login Fibre Channel port login acceptNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS FC Product Manual, Rev. B Temperature page 0Dh Cheetah NS FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Sense 10 Byte Header Data Mode Data Header Miscellaneous features Miscellaneous operating features and conditionsSupported Feature or condition Miscellaneous statusPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typePin Signal name Signal type Fault LED Out PowerMotor start controls Enable port bypass signalsActive LED Out 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIHex Dec SettingArbitrated loop physical address Alpa values Device control codes Signal characteristicsTTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Internet Seagate Technology support servicesPresales Support Technical SupportData Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Numerics IndexFAN Flogi Plogi SEL ID See also cooling