Seagate ST3400755FC, ST3300955FC Arbitrated loop physical address Alpa values, Setting, Hex Dec

Page 77

Table 24:

Arbitrated loop physical address (AL_PA) values

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AL_PA

SEL ID

Setting

 

AL_PA

SEL ID

Setting

 

AL_PA

SEL ID

Setting

(hex)

(hex)

(dec)

 

(hex)

(hex)

(dec)

 

(hex)

(hex)

(dec)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EF

00

00

 

A3

2B

43

 

4D

56

86

E8

01

01

 

9F

2C

44

 

4C

57

87

 

 

 

 

 

 

 

 

 

 

 

E4

02

02

 

9E

2D

45

 

4B

58

88

E2

03

03

 

9D

2E

46

 

4A

59

89

 

 

 

 

 

 

 

 

 

 

 

E1

04

04

 

9B

2F

47

 

49

5A

90

E0

05

05

 

98

30

48

 

47

5B

91

 

 

 

 

 

 

 

 

 

 

 

DC

06

06

 

97

31

49

 

46

5C

92

DA

07

07

 

90

32

50

 

45

5D

93

 

 

 

 

 

 

 

 

 

 

 

D9

08

08

 

8F

33

51

 

43

5E

94

D6

09

09

 

88

34

52

 

3c

5F

95

 

 

 

 

 

 

 

 

 

 

 

D5

0A

10

 

84

35

53

 

3A

60

96

D4

0B

11

 

82

36

54

 

39

61

97

 

 

 

 

 

 

 

 

 

 

 

D3

0C

12

 

81

37

55

 

36

62

98

D2

0D

13

 

80

38

56

 

35

63

99

 

 

 

 

 

 

 

 

 

 

 

D1

0E

14

 

7C

39

57

 

34

64

100

CE

0F

15

 

7A

3A

58

 

33

65

101

 

 

 

 

 

 

 

 

 

 

 

CD

10

16

 

79

3B

59

 

32

66

102

CC

11

17

 

76

3C

60

 

31

67

103

 

 

 

 

 

 

 

 

 

 

 

CB

12

18

 

75

3D

61

 

2E

68

104

CA

13

19

 

74

3E

62

 

2D

69

105

 

 

 

 

 

 

 

 

 

 

 

C9

14

20

 

73

3F

63

 

2C

6A

106

C7

15

21

 

72

40

64

 

2B

6B

107

 

 

 

 

 

 

 

 

 

 

 

C6

16

22

 

71

41

65

 

2A

6C

108

C5

17

23

 

6E

42

66

 

29

6D

109

 

 

 

 

 

 

 

 

 

 

 

C3

18

24

 

6D

43

67

 

27

6E

110

BC

19

25

 

6C

44

68

 

26

6F

111

 

 

 

 

 

 

 

 

 

 

 

BA

1A

26

 

6B

45

69

 

25

70

112

B9

1B

27

 

6A

46

70

 

23

71

113

 

 

 

 

 

 

 

 

 

 

 

B6

1C

28

 

69

47

71

 

1F

72

114

B5

1D

29

 

67

48

72

 

1E

73

115

 

 

 

 

 

 

 

 

 

 

 

B4

1E

30

 

66

49

73

 

1D

74

116

B3

1F

31

 

65

4A

74

 

1B

75

117

 

 

 

 

 

 

 

 

 

 

 

B2

20

32

 

63

4B

75

 

18

76

118

B1

21

33

 

5C

4C

76

 

17

77

119

 

 

 

 

 

 

 

 

 

 

 

AE

22

34

 

5A

4D

77

 

10

78

120

AD

23

35

 

59

4E

78

 

0F

79

121

 

 

 

 

 

 

 

 

 

 

 

AC

24

36

 

56

4F

79

 

08

7A

122

AB

25

37

 

55

50

80

 

04

7B

123

 

 

 

 

 

 

 

 

 

 

 

AA

26

38

 

54

51

81

 

02

7C

124

A9

27

39

 

53

52

82

 

01

7D

125

 

 

 

 

 

 

 

 

 

 

 

A7

28

40

 

52

53

83

 

 

 

 

A6

29

41

 

51

54

84

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A5

2A

42

 

4E

55

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cheetah NS FC Product Manual, Rev. B

67

Image 77
Contents ST3400755FC ST3300955FC Cheetah NS FCPage Cheetah NS FC Product Manual, Rev. B Cheetah NS FC Product Manual, Rev. B Contents Interface requirements Defect and error managementInstallation Seagate Technology support services Cheetah NS FC Product Manual, Rev. B List of Figures Page Scope Cheetah NS FC Product Manual, Rev. B Standards Standards, compliance and reference documentsElectromagnetic compatibility Electromagnetic susceptibilityCompliance Ncits TR-19 Reference documentsCheetah NS FC Product Manual, Rev. B General description Media description Standard featuresReliability PerformanceFormatted capacities Programmable drive capacityUser-installed accessories Factory-installed optionsInternal drive characteristics Performance characteristicsAccess time Seek performanceStart/stop time Format command execution time minutesGeneral performance characteristics Caching write data Prefetch/multi-segmented cache controlCache operation Prefetch operation Error rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenanceControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact MillisecondsDetermining rate Reporting controlPredictive failures Thermal monitorParameter Code Description State of the drive prior to testingDrive Self Test DST DST failure definitionShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bAbort Product warrantyShipping Product repair and return informationCheetah NS FC Product Manual, Rev. B AC power requirements Physical/electrical specificationsDC power requirements DC power requirements for ST3400755FC model Gbit AmpsDC power requirements for ST3300955FC model Gbit Amps General DC power requirement notesConducted noise immunity Power sequencingCurrent profiles Cheetah NS FC Product Manual, Rev. B ST3400755 CURRENT/POWER vs Throughput FC 4GB Power dissipationST3400755FC Random 8 Block ReadsST3300955FC ST3300955 CURRENT/POWER vs Throughput FC 4GBRelative humidity TemperatureEnvironmental limits Effective altitude sea level Package size Packaged/product weight Drop heightShock and vibration ShockRecommended mounting Vibration Air cleanlinessAcoustics Corrosive environmentChina Restriction of Hazardous Substances RoHS Directive X表示该部件(于同类物品程度上)所含的危险和有毒物质中国RoHS MCV标准所定义的门槛值。Mounting configuration dimensions Mechanical specificationsCheetah NS FC Product Manual, Rev. B Drive error recovery procedures Defect and error managementDrive internal defects/errors 77.87 Media Pre-Scan FC-AL system errorsBackground Media Scan Idle Read After Write Deferred Auto-ReallocationDrive ID/option selection InstallationDrive orientation CoolingAir flow Drive mountingGrounding Cheetah NS FC Product Manual, Rev. B Fibre Channel link service frames FC-AL featuresLink services supported Type of frame Interface requirementsFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses NPort login Plogi payload Bytes Fibre Channel port loginFibre Channel Process Login Fibre Channel port login acceptNPort Login Accept ACC payload Bytes Process Login Plri payloadFibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Bytes Fabric Login Flogi payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS FC Product Manual, Rev. B Temperature page 0Dh Cheetah NS FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Sense 10 Byte Header Data Mode Data Header Miscellaneous features Miscellaneous operating features and conditionsSupported Feature or condition Miscellaneous statusPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typePin Signal name Signal type Fault LED Out PowerMotor start controls Enable port bypass signalsActive LED Out 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIHex Dec SettingArbitrated loop physical address Alpa values Device control codes Signal characteristicsTTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Internet Seagate Technology support servicesPresales Support Technical SupportData Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Numerics IndexFAN Flogi Plogi SEL ID See also cooling
Related manuals
Manual 90 pages 49.16 Kb