Seagate ST3300955FC, ST3400755FC manual Plogi

Page 86

Queue tagging 60

 

 

Reporting actual retry count

60

Segmented caching

60

 

SMP = 1 in Mode Select command 60

Synchronized (locked) spindle operation 60

Zero latency read

60

 

miscellaneous status support

 

ACA active

60

 

 

 

ACA active, faulted initiator

60

Busy

60

 

 

 

 

Check condition

60

 

 

Condition met/good

60

 

Good

60

 

 

 

 

Intermediate/condition met/good 60

Intermediate/good 60

 

Reservation conflict

60

 

Task set full

60

 

 

 

miscorrected media data

15

 

Mode select

 

 

 

 

(10)command 55 command 52

Mode sense

(10)command 55 command 52 data, table 56, 58

monitoring state 16 motor start

controls 65 mounting 42

holes 42 orientations 41

Mounting configuration dimensions 35 MTBF 16

N

N_Port Login (PLOGI) 45 payload 47 payload values 48

NN47, 50 Node Name 50 Node name 47 noise

audible 3 noise immunity 25

non-operating 30, 31, 33 temperature 30

non-operating vibration 33

O

office environment 33 old port state

FC-AL options 51 OPEN Full Duplex

FC-AL options 51

OPEN half duplex FC-AL options 51

Open sequences per exchange 47 operating 30, 31, 33

option configurations 41 option selection 62 options 10, 51 orientation 31

OS 47

out-of-plane distortion 42

P

P_LOGI

received on Port A 48 received on Port B 48

package size 31

package test specification 5 packaged 31

parameter rounding 60 pass-through state 16 PBC 61, 65 PBdata 54

PCBA 43

peak bits per inch 11

peak operating current 23, 24 peak-to-peak measurements 25 performance characteristics

detailed 11 general 12

performance degradation 31 performance highlights 9 physical damage 33 physical interface 61

description 61 physical specifications 23 PI 48, 49

pin descriptions 62 PN 47, 50

port bypass circuit 16, 17, 61, 65 Port DISCovery 47

Port Discovery (PDISC) 45 port identifier field 48, 49 port login 47

accept 48 Port Name 50

Port name (initiator’s) 47 power 64

dissipation 28 requirements, AC 23 requirements, DC 23 sequencing 25

Power control page (1Ah) command 53 power distribution 3

power failure warning 68 Prefetch command 54

76

Cheetah NS FC Product Manual, Rev. B

Image 86
Contents Cheetah NS FC ST3400755FC ST3300955FCPage Cheetah NS FC Product Manual, Rev. B Cheetah NS FC Product Manual, Rev. B Contents Interface requirements Defect and error managementInstallation Seagate Technology support services Cheetah NS FC Product Manual, Rev. B List of Figures Page Scope Cheetah NS FC Product Manual, Rev. B Electromagnetic compatibility Standards, compliance and reference documentsStandards Electromagnetic susceptibilityCompliance Reference documents Ncits TR-19Cheetah NS FC Product Manual, Rev. B General description Standard features Media descriptionFormatted capacities PerformanceReliability Programmable drive capacityFactory-installed options User-installed accessoriesAccess time Performance characteristicsInternal drive characteristics Seek performanceStart/stop time Format command execution time minutesGeneral performance characteristics Caching write data Prefetch/multi-segmented cache controlCache operation Prefetch operation Recoverable Errors Reliability specificationsError rates Unrecoverable ErrorsInterface errors Reliability and serviceSeek errors Preventive maintenancePerformance impact 4 S.M.A.R.TControlling S.M.A.R.T MillisecondsPredictive failures Reporting controlDetermining rate Thermal monitorDrive Self Test DST State of the drive prior to testingParameter Code Description DST failure definitionShort test Function Code 001b Invoking DSTShort and extended tests Extended test Function Code 010bShipping Product warrantyAbort Product repair and return informationCheetah NS FC Product Manual, Rev. B DC power requirements Physical/electrical specificationsAC power requirements DC power requirements for ST3400755FC model Gbit AmpsGeneral DC power requirement notes DC power requirements for ST3300955FC model Gbit AmpsPower sequencing Conducted noise immunityCurrent profiles Cheetah NS FC Product Manual, Rev. B ST3400755FC Power dissipationST3400755 CURRENT/POWER vs Throughput FC 4GB Random 8 Block ReadsST3300955 CURRENT/POWER vs Throughput FC 4GB ST3300955FCRelative humidity TemperatureEnvironmental limits Shock and vibration Package size Packaged/product weight Drop heightEffective altitude sea level ShockRecommended mounting Acoustics Air cleanlinessVibration Corrosive environmentX表示该部件(于同类物品程度上)所含的危险和有毒物质中国RoHS MCV标准所定义的门槛值。 China Restriction of Hazardous Substances RoHS DirectiveMechanical specifications Mounting configuration dimensionsCheetah NS FC Product Manual, Rev. B Drive error recovery procedures Defect and error managementDrive internal defects/errors 77.87 Media Pre-Scan FC-AL system errorsBackground Media Scan Deferred Auto-Reallocation Idle Read After WriteDrive orientation InstallationDrive ID/option selection CoolingDrive mounting Air flowGrounding Cheetah NS FC Product Manual, Rev. B Link services supported Type of frame FC-AL featuresFibre Channel link service frames Interface requirementsFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses Fibre Channel port login NPort login Plogi payload BytesNPort Login Accept ACC payload Bytes Fibre Channel port login acceptFibre Channel Process Login Process Login Plri payloadProcess Login Accept ACC payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesFC-AL options supported Dual port supportFibre Channel Arbitrated Loop options Option SupportedScsi commands supported Supported commands Command code Command nameVerify error recovery page 07h Cheetah NS FC Product Manual, Rev. B Temperature page 0Dh Cheetah NS FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Sense 10 Byte Header Data Mode Data Header Supported Feature or condition Miscellaneous operating features and conditionsMiscellaneous features Miscellaneous statusPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typePin Signal name Signal type Power Fault LED OutMotor start controls Enable port bypass signalsActive LED Out Parallel Enclosure Services Interface ESI 11 SEL6 through SEL0 ID linesHex Dec SettingArbitrated loop physical address Alpa values Device control codes Signal characteristicsTTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Presales Support Seagate Technology support servicesInternet Technical SupportData Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Index NumericsFAN Flogi Plogi SEL ID See also cooling
Related manuals
Manual 90 pages 49.16 Kb