12 volt pins 64

3rd party reserve command 55 5 volt pins 64

A

Abort Sequence (ABTS)

45

 

 

abort task set function

46

 

 

AC coupling 63

 

 

 

 

 

AC power requirements

23

 

 

ACA active status

60

 

 

 

 

ACA active, faulted initiator status

60

Accept (ACC)

45

 

 

 

 

 

acoustics

33

 

 

 

 

 

 

active LED Out signal

65

 

 

Actual retry count bytes command

52

actuator

 

 

 

 

 

 

 

 

assembly design

7

 

 

 

adaptive caching

60

 

 

 

 

Address Discovery (ADISC)

45

 

addresses

61

 

 

 

 

 

 

AFR 15

 

 

 

 

 

 

 

 

air cleanliness

33

 

 

 

 

 

air flow

42

 

 

 

 

 

 

illustrated

42

 

47,

 

 

Alternate credit model

50

 

altitude

31

 

 

 

 

 

 

ambient

30

 

 

 

 

 

 

Annualized Failure Rates (AFR) 16

ANSI documents

 

 

 

 

 

fibre channel

5

 

 

 

 

SCSI

5

 

 

 

 

 

 

arbitrated loop physical address (AL_PA) 41

arbitration 41

 

 

 

asynchronous event notification

60

audible noise 3

 

 

 

auto negotiation of link rate 68

 

auto write and read reallocation

 

programmable

8

 

 

automatic contingent allegiance

60

average idle current

23,

24

 

average rotational latency

11

 

B

Background Media Scan

39

backpanel

62

 

backplane

65

 

basic link service frames

45

Basic_Accept (BA_ACC)

45

Basic_Reject (BA_RJT)

45

BB 47, 50 BB-Credit 47, 50 BMS 39

buffer data 8 space 13

busy status 60 bypass circuit 16

Byte check command 53 bytes per track 11

C

cache operation 13 cache segments 13

Caching parameters page (08h) command 53 caching write data 13

Canadian Department of Communications 3 capacity

unformatted 11

capacity, drive, programmable 9

CC48, 49 CF 47, 50

Change definition command 54 character sync 16

charge pins 64

check condition status 60 Class 3 parameters 47, 50 class B limit 3

Class valid 47, 50 clear ACA function 46 clear task set function 46 commands supported 52 Common features 47, 50 Company ID 48, 49 Compare command 54 Concurrent sequences 47 condensation 30 condition met/good status 60 connector

illustrated 62 requirements 62

continuous vibration 33

Continuously increasing offset 47, 50 control code values 68

Control mode page (0Ah) command 53 cooling 41

Copy and verify command 54 Copy command 52

CRC 16 error 16

CS 47

Current profiles 26 customer service 21

Cheetah NS FC Product Manual, Rev. B

73

Image 83
Contents ST3400755FC ST3300955FC Cheetah NS FCPage Cheetah NS FC Product Manual, Rev. B Cheetah NS FC Product Manual, Rev. B Contents Interface requirements Defect and error managementInstallation Seagate Technology support services Cheetah NS FC Product Manual, Rev. B List of Figures Page Scope Cheetah NS FC Product Manual, Rev. B Electromagnetic susceptibility Standards, compliance and reference documentsStandards Electromagnetic compatibilityCompliance Ncits TR-19 Reference documentsCheetah NS FC Product Manual, Rev. B General description Media description Standard featuresProgrammable drive capacity PerformanceReliability Formatted capacitiesUser-installed accessories Factory-installed optionsSeek performance Performance characteristicsInternal drive characteristics Access timeStart/stop time Format command execution time minutesGeneral performance characteristics Caching write data Prefetch/multi-segmented cache controlCache operation Prefetch operation Unrecoverable Errors Reliability specificationsError rates Recoverable ErrorsPreventive maintenance Reliability and serviceSeek errors Interface errorsMilliseconds 4 S.M.A.R.TControlling S.M.A.R.T Performance impactThermal monitor Reporting controlDetermining rate Predictive failuresDST failure definition State of the drive prior to testingParameter Code Description Drive Self Test DSTExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bProduct repair and return information Product warrantyAbort ShippingCheetah NS FC Product Manual, Rev. B DC power requirements for ST3400755FC model Gbit Amps Physical/electrical specificationsAC power requirements DC power requirementsDC power requirements for ST3300955FC model Gbit Amps General DC power requirement notesConducted noise immunity Power sequencingCurrent profiles Cheetah NS FC Product Manual, Rev. B Random 8 Block Reads Power dissipationST3400755 CURRENT/POWER vs Throughput FC 4GB ST3400755FCST3300955FC ST3300955 CURRENT/POWER vs Throughput FC 4GBRelative humidity TemperatureEnvironmental limits Shock Package size Packaged/product weight Drop heightEffective altitude sea level Shock and vibrationRecommended mounting Corrosive environment Air cleanlinessVibration AcousticsChina Restriction of Hazardous Substances RoHS Directive X表示该部件(于同类物品程度上)所含的危险和有毒物质中国RoHS MCV标准所定义的门槛值。Mounting configuration dimensions Mechanical specificationsCheetah NS FC Product Manual, Rev. B Drive error recovery procedures Defect and error managementDrive internal defects/errors 77.87 Media Pre-Scan FC-AL system errorsBackground Media Scan Idle Read After Write Deferred Auto-ReallocationCooling InstallationDrive ID/option selection Drive orientationAir flow Drive mountingGrounding Cheetah NS FC Product Manual, Rev. B Interface requirements FC-AL featuresFibre Channel link service frames Link services supported Type of frameFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses NPort login Plogi payload Bytes Fibre Channel port loginProcess Login Plri payload Fibre Channel port login acceptFibre Channel Process Login NPort Login Accept ACC payload BytesFabric Login Flogi payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Process Login Accept ACC payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS FC Product Manual, Rev. B Temperature page 0Dh Cheetah NS FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Sense 10 Byte Header Data Mode Data Header Miscellaneous status Miscellaneous operating features and conditionsMiscellaneous features Supported Feature or conditionPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typePin Signal name Signal type Fault LED Out PowerMotor start controls Enable port bypass signalsActive LED Out 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIHex Dec SettingArbitrated loop physical address Alpa values Device control codes Signal characteristicsTTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Technical Support Seagate Technology support servicesInternet Presales SupportData Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Numerics IndexFAN Flogi Plogi SEL ID See also cooling
Related manuals