Seagate ST3500071FC manual Invoking DST, Short and extended tests, Short test Function Code 001b

Page 31

5.2.6.2.2Invoking DST

To invoke DST, submit the Send Diagnostic command with the appropriate Function Code (001b for the short test or 010b for the extended test) in bytes 1, bits 5, 6, and 7. Refer to the Fibre Channel Interface Product Manual, part number 77767496, for additional information about invoking DST.

5.2.6.2.3Short and extended tests

DST has two testing options:

1.short

2.extended

These testing options are described in the following two subsections.

Each test consists of three segments: an electrical test segment, a servo test segment, and a read/verify scan segment.

Short test (Function Code: 001b)

The purpose of the short test is to provide a time-limited test that tests as much of the drive as possible within 120 seconds. The short test does not scan the entire media surface, but does some fundamental tests and scans portions of the media. A complete read/verify scan is not performed and only factual failures will report a fault condition. This option provides a quick confidence test of the drive.

Extended test (Function Code: 010b)

The objective of the extended test option is to empirically test critical drive components. For example, the seek tests and on-track operations test the positioning mechanism. The read operation tests the read head element and the media surface. The write element is tested through read/write/read operations. The integrity of the media is checked through a read/verify scan of the media. Motor functionality is tested by default as a part of these tests.

The anticipated length of the Extended test is reported through the Control Mode page.

5.2.6.2.4Log page entries

When the drive begins DST, it creates a new entry in the Self-test Results Log page. The new entry is created by inserting a new self-test parameter block at the beginning of the self-test results log parameter section of the log page. Existing data will be moved to make room for the new parameter block. The drive reports 20 param- eter blocks in the log page. If there are more than 20 parameter blocks, the least recent parameter block will be deleted. The new parameter block will be initialized as follows:

1.The Function Code field is set to the same value as sent in the DST command

2.The Self-Test Results Value field is set to Fh

3.The drive will store the log page to non-volatile memory

After a self-test is complete or has been aborted, the drive updates the Self-Test Results Value field in its Self- Test Results Log page in non-volatile memory. The host may use Log Sense to read the results from up to the last 20 self-tests performed by the drive. The self-test results value is a 4-bit field that reports the results of the test. If the field is zero, the drive passed with no errors detected by the DST. If the field is not zero, the test failed for the reason reported in the field.

The drive will report the failure condition and LBA (if applicable) in the Self-test Results Log parameter. The Sense key, ASC, ASCQ, and FRU are used to report the failure condition.

NL35 Series FC Product Manual, Rev. D

23

Image 31
Contents ST3500071FC ST3400071FC NL35 Series FCPage Contents Installation Defect and error managementInterface requirements Seagate Technology support services NL35 Series FC Product Manual, Rev. D NL35 Series family disc drive List of FiguresViii NL35 Series FC Product Manual, Rev. D NL35 Series family disc drive ScopeNL35 Series FC Product Manual, Rev. D Electromagnetic susceptibility Applicable standards and reference documentationStandards Electromagnetic compatibilityEnvironmental protection Electromagnetic complianceFibre Channel Interface Manual Reference documentsNL35 Series FC Product Manual, Rev. D General description Standard features Formatted capacities Media descriptionPerformance ReliabilityProgrammable drive capacity Factory-installed accessoriesFactory-installed options User-installed accessoriesAccess time Performance characteristicsInternal drive characteristics Seek performance characteristicsGHz Generalized performance characteristicsPrefetch/multi-segmented cache control Start/stop timeCache operation Prefetch operation Caching write dataPage NL35 Series FC Product Manual, Rev. D Error rates Reliability specificationsSeek errors Reliability and serviceRecoverable Errors Unrecoverable errorsMean Time Between Failure Mtbf Preventive maintenanceHot plugging the drive Milliseconds 4 S.M.A.R.TControlling S.M.A.R.T Performance impactParameter Code Description Temperature Log page 0DhPredictive failures Thermal monitorImplementation State of the drive prior to testingDrive Self Test DST DST Failure DefinitionExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bProduct repair and return information Product warrantyAbort ShippingST3500071FC/ST3400071FC DC power requirements Physical/electrical specificationsAC power requirements DC power requirementsPower sequencing General DC power requirement notesConducted noise immunity Power dissipation Effective altitude sea level TemperatureEnvironmental limits Relative humidityShock and vibration Package size Packaged/product weight Drop heightShock Recommended mounting Vibration Air cleanlinessCorrosive environment Typical idle mode sound power ST3500071FC and ST3400071FCAcoustics Mounting configuration dimensions Mechanical specificationsNL35 Series FC Product Manual, Rev. D Drive internal defects/errors Defect and error managementDrive error recovery procedures 108.3 Background Media Scan FC-AL system errorsMedia Pre-Scan NL35 Series FC Product Manual, Rev. D Drive ID/option selection InstallationDrive orientation Air flow CoolingGrounding Drive mountingNL35 Series FC Product Manual, Rev. D Type of frame Link service FC-AL featuresFibre Channel link service frames Link services supportedFC Scsi FCP response codes Fibre Channel task management functionsFibre Channel Scsi FCP task management functions Fibre Channel task management responsesNPort login Plogi payload Fibre Channel port loginBytes Process Login Plri payload Fibre Channel port login acceptNPort Login Accept ACC payload Fibre Channel Process LoginFabric Login Flogi payload Fibre Channel Process Login AcceptProcess Login Accept ACC payload Fibre Channel fabric loginFabric Login Accept ACC payload Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Scsi commands supportedCommand code Supported Command name Supported commands Supported commands Supported commands Supported commands Bytes Data hex Mode Sense dataInquiry data NL35 Series inquiry dataPage DEF CHG NL35 Series FC Product Manual, Rev. D Miscellaneous status Miscellaneous operating features and conditionsMiscellaneous features Supported Feature or conditionFC-AL physical interface Physical characteristicsPhysical description Part description Positions Part number Features Connector requirementsElectrical description Pin descriptions Pin Signal name Signal typeFC-SCA pin descriptions Fault LED Out PowerFC-AL transmitters and receivers Active LED Out conditions Enable port bypass signalsNormal command activity LED status Active LED Out11 SEL6 through SEL0 ID lines Motor start control signalsParallel Enclosure Services Interface ESI Motor start controlsArbitrated loop physical address Alpa values SettingHex Dec Signal characteristics Differential Pecl input characteristics LED driver signalsLED drive signal Differential Pecl output characteristicsLink rate GHz Eye diagram data valuesNL35 Series FC Product Manual, Rev. D Technical Support Seagate Technology support servicesInternet Presales SupportData Recovery Services Authorized Service Centers Warranty ServiceData Recovery Services Call Center Toll-free Direct dial Numerics IndexFAN Flogi Plogi Page See also cooling