Seagate ST3400071FC, ST3500071FC manual Plogi

Page 84

Queue tagging 59

 

 

Reporting actual retry count

59

Segmented caching

59

 

SMP = 1 in Mode Select command 59

Synchronized (locked) spindle operation 59

Zero latency read

59

 

miscellaneous status support

 

ACA active

59

 

 

 

ACA active, faulted initiator

59

Busy

59

 

 

 

 

Check condition

59

 

 

Condition met/good

59

 

Good

59

 

 

 

 

Intermediate/condition met/good 59

Intermediate/good 59

 

Reservation conflict

59

 

Task set full

59

 

 

 

miscorrected media data

17

 

Mode select

 

 

 

 

(10)command 54 command 50

Mode sense

(10)command 54 command 51

data, table 55, 57, 58

monitoring state 19 motor start

controls 65 option 13

mounting 41 holes 41 orientations 39

mounting configuration 33

mounting configuration dimensions 33 MTBF 19

N

N_Port Login (PLOGI) 43 payload 45 payload values 46

NN45, 48 Node Name 48 Node name 45 noise

audible 3 noise immunity 26

non-operating 28, 29, 31 temperature 28

non-operating vibration 31

O

office environment 31 old port state

FC-AL options 49

OPEN Full Duplex

 

 

 

FC-AL options

49

 

OPEN half duplex

 

 

 

FC-AL options

49

 

Open sequences per exchange

45

operating 28, 29, 31

 

operating environment

19

 

option configurations

39

 

option selection 61

 

 

 

options 10,

49

 

 

 

orientation

12

 

 

 

OS 45

 

 

 

 

out-of-plane distortion

41

 

overhead time

 

 

 

for head switch

12

 

for one track cylinder switch

12

P

P_LOGI

received on Port A 46 received on Port B 46

package size 29

package test specification 5 packaged 29

parameter rounding 59 pass-through state 19 PBC 60, 64 PBdata 53

PCBA 41

peak bits per inch 11 peak operating current 25 PECL input 68 performance characteristics

detailed 11 performance degradation 29 performance highlights 9 physical damage 31 physical interface 60

description 60 physical specifications 25 PI 46, 47

pin descriptions 62 PN 45, 48

port bypass circuit 19, 60, 64 Port DISCovery 45

Port Discovery (PDISC) 43 port identifier field 46, 47 port login 45

accept 46 Port Name 48

Port name (initiator’s) 45 power 63

dissipation 27 requirements, AC 25 requirements, DC 25

76

NL35 Series FC Product Manual, Rev. D

Image 84
Contents NL35 Series FC ST3500071FC ST3400071FCPage Contents Defect and error management InstallationInterface requirements Seagate Technology support services NL35 Series FC Product Manual, Rev. D List of Figures NL35 Series family disc driveViii NL35 Series FC Product Manual, Rev. D Scope NL35 Series family disc driveNL35 Series FC Product Manual, Rev. D Applicable standards and reference documentation StandardsElectromagnetic compatibility Electromagnetic susceptibilityElectromagnetic compliance Environmental protectionReference documents Fibre Channel Interface ManualNL35 Series FC Product Manual, Rev. D General description Standard features Media description PerformanceReliability Formatted capacitiesFactory-installed accessories Factory-installed optionsUser-installed accessories Programmable drive capacityPerformance characteristics Internal drive characteristicsSeek performance characteristics Access timeGeneralized performance characteristics GHzStart/stop time Prefetch/multi-segmented cache controlCache operation Caching write data Prefetch operationPage NL35 Series FC Product Manual, Rev. D Reliability specifications Error ratesReliability and service Recoverable ErrorsUnrecoverable errors Seek errorsPreventive maintenance Mean Time Between Failure MtbfHot plugging the drive 4 S.M.A.R.T Controlling S.M.A.R.TPerformance impact MillisecondsTemperature Log page 0Dh Predictive failuresThermal monitor Parameter Code DescriptionState of the drive prior to testing Drive Self Test DSTDST Failure Definition ImplementationInvoking DST Short and extended testsShort test Function Code 001b Extended test Function Code 010bProduct warranty AbortShipping Product repair and return informationPhysical/electrical specifications AC power requirementsDC power requirements ST3500071FC/ST3400071FC DC power requirementsGeneral DC power requirement notes Power sequencingConducted noise immunity Power dissipation Temperature Environmental limitsRelative humidity Effective altitude sea levelPackage size Packaged/product weight Drop height Shock and vibrationShock Recommended mounting Air cleanliness VibrationTypical idle mode sound power ST3500071FC and ST3400071FC Corrosive environmentAcoustics Mechanical specifications Mounting configuration dimensionsNL35 Series FC Product Manual, Rev. D Defect and error management Drive internal defects/errorsDrive error recovery procedures 108.3 FC-AL system errors Background Media ScanMedia Pre-Scan NL35 Series FC Product Manual, Rev. D Installation Drive ID/option selectionDrive orientation Cooling Air flowDrive mounting GroundingNL35 Series FC Product Manual, Rev. D FC-AL features Fibre Channel link service framesLink services supported Type of frame Link serviceFibre Channel task management functions Fibre Channel Scsi FCP task management functionsFibre Channel task management responses FC Scsi FCP response codesFibre Channel port login NPort login Plogi payloadBytes Fibre Channel port login accept NPort Login Accept ACC payloadFibre Channel Process Login Process Login Plri payloadFibre Channel Process Login Accept Process Login Accept ACC payloadFibre Channel fabric login Fabric Login Flogi payloadFibre Channel fabric accept login Fabric Login Accept ACC payloadDual port support Fibre Channel Arbitrated Loop optionsFC-AL options supported Option SupportedScsi commands supported Supported commandsCommand code Supported Command name Supported commands Supported commands Supported commands Supported commands Mode Sense data Inquiry dataNL35 Series inquiry data Bytes Data hexPage DEF CHG NL35 Series FC Product Manual, Rev. D Miscellaneous operating features and conditions Miscellaneous featuresSupported Feature or condition Miscellaneous statusPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Part description Positions Part number FeaturesElectrical description Pin Signal name Signal type Pin descriptionsFC-SCA pin descriptions Power Fault LED OutFC-AL transmitters and receivers Enable port bypass signals Normal command activity LED statusActive LED Out Active LED Out conditionsMotor start control signals Parallel Enclosure Services Interface ESIMotor start controls 11 SEL6 through SEL0 ID linesSetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics LED driver signals LED drive signalDifferential Pecl output characteristics Differential Pecl input characteristicsEye diagram data values Link rate GHzNL35 Series FC Product Manual, Rev. D Seagate Technology support services InternetPresales Support Technical SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Index NumericsFAN Flogi Plogi Page See also cooling