6.4.4.2Vibration
a.Operating - normal
The drive as installed for normal operation, shall comply with the complete specified performance while subjected to continuous vibration not exceeding
Vibration may be applied in the X, Y, or Z axis.
Operating normal translational random flat profile
10 - 500 Hz | 0.5 G RMS (grams root mean square) |
b.Operating - abnormal
Equipment as installed for normal operation shall not incur physical damage while subjected to periodic vibration not exceeding:
15 minutes of duration at major resonant frequency
Vibration occurring at these levels may degrade operational performance during the abnormal vibration period. Specified operational performance will continue when normal operating vibration levels are resumed. This assumes system recovery routines are available.
Operating abnormal translational random flat profile
10 - 500 Hz | 1.2 G RMS (grams root mean square) |
c.
The limits of
The drive shall not incur physical damage or degraded performance as a result of continuous vibration not exceeding
Vibration may be applied in the X, Y, or Z axis.
10 - 500 Hz | 1.2 G RMS (grams root mean square) |
6.4.5Air cleanliness
The drive is designed to operate in a typical office environment with minimal environmental control.
NL35 Series FC Product Manual, Rev. D | 31 |