Page 73

9.5.10Motor start controls

The drive’s motor is started according to the Start_1 and Start_2 signals described in Table 31. The state of these signals can be wired into the backplane socket or driven by logic on the backplane.

Table 31:

Motor start control signals

 

 

 

 

 

Case

 

Start_2

Start_1

Motor spin function

 

 

 

 

 

1

 

Low

Low

Motor spins up at DC power on.

 

 

 

 

 

2

 

High

Low

Motor spins up only when SCSI Start command is received.

 

 

 

 

 

3

 

Low

High

Motor spins up after a delay of 12 seconds times the modulo 8 value of

 

 

 

 

the numeric SEL ID of the drive from DC power on.

 

 

 

 

 

4

 

High

High

The drive will not spin up.

 

 

 

 

 

9.5.11SEL_6 through SEL_0 ID lines

The SEL_6 through SEL_0 ID lines determine drive address, and, optionally, for an Enclosure Services Inter- face. When the Parallel ESI line is high, the enclosure backpanel must provide address information on the SEL line. Refer to table 32 for a mapping of SEL to FC-AL physical addresses (AL_PA). You can think of the SEL lines as the equivalent of a backpanel logic plug. The drives does not provide pull up resistors on these lines. The backpanel is required to provide high and low inputs to the SEL_ID lines per the specifications in table 34 on page 67.

Note. Table 32 gives AL_PA values for each SEL value. The first entry in the table is SEL_ID 00. The last entry is SEL_ID 7D. SEL_ID 7E is AL_PA 00 which is not valid for an NL_Port, so is not included in the table. Also, SEL_ID 7Fh does map to a valid AL_PA; however, this value signals the drive that physical addresses are not being assigned using the SEL lines and that a “soft” address will be determined by FC-AL loop initialization.

When the Parallel ESI line is low, the enclosure backpanel logic switches to ESI mode if supported. There are two modes of ESI, seven bits of enclosure status and a bidirectional mode. ESI support and the mode are determined by the drive using a discovery process. Refer to the Fibre Channel Interface Manual for a descrip- tion of ESI operation.

9.5.11.1Parallel Enclosure Services Interface (ESI)

The parallel ESI line is an output from the drive. This line provides the enclosure with an indication of the present function of the SEL lines. A high level, the default state, indicates the drive requires address informa- tion on the SEL lines. A low level indicates the drive is attempting an ESI transfer. The enclosure may not sup- port ESI on any or all drive locations. It may only support the address function. Support of ESI is discovered by the drive. Refer to the Fibre Channel Interface Manual for a description of ESI operations.

NL35 Series FC Product Manual, Rev. D

65

Image 73
Contents ST3500071FC ST3400071FC NL35 Series FCPage Contents Installation Defect and error managementInterface requirements Seagate Technology support services NL35 Series FC Product Manual, Rev. D NL35 Series family disc drive List of FiguresViii NL35 Series FC Product Manual, Rev. D NL35 Series family disc drive ScopeNL35 Series FC Product Manual, Rev. D Standards Applicable standards and reference documentationElectromagnetic compatibility Electromagnetic susceptibilityEnvironmental protection Electromagnetic complianceFibre Channel Interface Manual Reference documentsNL35 Series FC Product Manual, Rev. D General description Standard features Performance Media descriptionReliability Formatted capacitiesFactory-installed options Factory-installed accessoriesUser-installed accessories Programmable drive capacityInternal drive characteristics Performance characteristicsSeek performance characteristics Access timeGHz Generalized performance characteristicsPrefetch/multi-segmented cache control Start/stop timeCache operation Prefetch operation Caching write dataPage NL35 Series FC Product Manual, Rev. D Error rates Reliability specificationsRecoverable Errors Reliability and serviceUnrecoverable errors Seek errorsMean Time Between Failure Mtbf Preventive maintenanceHot plugging the drive Controlling S.M.A.R.T 4 S.M.A.R.TPerformance impact MillisecondsPredictive failures Temperature Log page 0DhThermal monitor Parameter Code DescriptionDrive Self Test DST State of the drive prior to testingDST Failure Definition ImplementationShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bAbort Product warrantyShipping Product repair and return informationAC power requirements Physical/electrical specificationsDC power requirements ST3500071FC/ST3400071FC DC power requirementsPower sequencing General DC power requirement notesConducted noise immunity Power dissipation Environmental limits TemperatureRelative humidity Effective altitude sea levelShock and vibration Package size Packaged/product weight Drop heightShock Recommended mounting Vibration Air cleanlinessCorrosive environment Typical idle mode sound power ST3500071FC and ST3400071FCAcoustics Mounting configuration dimensions Mechanical specificationsNL35 Series FC Product Manual, Rev. D Drive internal defects/errors Defect and error managementDrive error recovery procedures 108.3 Background Media Scan FC-AL system errorsMedia Pre-Scan NL35 Series FC Product Manual, Rev. D Drive ID/option selection InstallationDrive orientation Air flow CoolingGrounding Drive mountingNL35 Series FC Product Manual, Rev. D Fibre Channel link service frames FC-AL featuresLink services supported Type of frame Link serviceFibre Channel Scsi FCP task management functions Fibre Channel task management functionsFibre Channel task management responses FC Scsi FCP response codesNPort login Plogi payload Fibre Channel port loginBytes NPort Login Accept ACC payload Fibre Channel port login acceptFibre Channel Process Login Process Login Plri payloadProcess Login Accept ACC payload Fibre Channel Process Login AcceptFibre Channel fabric login Fabric Login Flogi payloadFabric Login Accept ACC payload Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedSupported commands Scsi commands supportedCommand code Supported Command name Supported commands Supported commands Supported commands Supported commands Inquiry data Mode Sense dataNL35 Series inquiry data Bytes Data hexPage DEF CHG NL35 Series FC Product Manual, Rev. D Miscellaneous features Miscellaneous operating features and conditionsSupported Feature or condition Miscellaneous statusFC-AL physical interface Physical characteristicsPhysical description Part description Positions Part number Features Connector requirementsElectrical description Pin descriptions Pin Signal name Signal typeFC-SCA pin descriptions Fault LED Out PowerFC-AL transmitters and receivers Normal command activity LED status Enable port bypass signalsActive LED Out Active LED Out conditionsParallel Enclosure Services Interface ESI Motor start control signalsMotor start controls 11 SEL6 through SEL0 ID linesArbitrated loop physical address Alpa values SettingHex Dec Signal characteristics LED drive signal LED driver signalsDifferential Pecl output characteristics Differential Pecl input characteristicsLink rate GHz Eye diagram data valuesNL35 Series FC Product Manual, Rev. D Internet Seagate Technology support servicesPresales Support Technical SupportData Recovery Services Authorized Service Centers Warranty ServiceData Recovery Services Call Center Toll-free Direct dial Numerics IndexFAN Flogi Plogi Page See also cooling